PC24QIN0 is a standard ABAP INCLUDE available within your SAP system (depending on your version and release level). Below is the basic information available for this SAP report including which OBJECTS it interacts with such as TABLES, FUNCTION MODULES, INCLUDES ETC. Also check out the submitted Comments related to this SAP report or see any standard documentation available.
If you would like to execute this report or see the full code listing simply enter PC24QIN0 into the relevant SAP transactions such as SE38 or SE80
This report can be called from another progam/report simply by using the ABAP SUBMIT statement, see below for example ABAP code snipts of how to do this.
Title: Include PC24QIN0
No INCLUDES are used within this REPORT code!
No SAP DATABASE tables are accessed within this REPORT code!
ADDR_GET CALL FUNCTION 'ADDR_GET' EXPORTING ADDRESS_SELECTION = SELECTION ADDRESS_GROUP = 'CA01' "to read SADR for unchanged IMPORTING "data ADDRESS_VALUE = ADDR1_VAL "both structures filled SADR = SADR "choose one of them EXCEPTIONS ADDRESS_NOT_EXIST = 1 OTHERS = 2. "SADR40A
GUI_DOWNLOAD CALL FUNCTION 'GUI_DOWNLOAD' EXPORTING FILENAME = TEMP_PATH FILETYPE = 'ASC' TRUNC_TRAILING_BLANKS = 'X' TABLES DATA_TAB = FINAL_DUMP EXCEPTIONS FILE_WRITE_ERROR = 2.
RP_LAST_DAY_OF_MONTHS CALL FUNCTION 'RP_LAST_DAY_OF_MONTHS' EXPORTING DAY_IN = F16_BEGDA IMPORTING LAST_DAY_OF_MONTH = F16_MNTH_ENDDA.
HR_IN_ROUND_AMT CALL FUNCTION 'HR_IN_ROUND_AMT' EXPORTING AMOUNT = QMAIN_TAB-TAX_PAYABLE RNDOFF = 100 RNDLMT = 'N' IMPORTING RETAMT = QMAIN_TAB-TAX_PAYABLE.
REUSE_ALV_FIELDCATALOG_MERGE CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE' EXPORTING I_PROGRAM_NAME = 'HINCF24Q' I_INTERNAL_TABNAME = 'ANNEX_I' I_INCLNAME = 'PC24QIN2' "RDP 07.05.2005
REUSE_ALV_GRID_DISPLAY CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY' EXPORTING I_CALLBACK_PROGRAM = REPID I_CALLBACK_PF_STATUS_SET = 'SET_PF_STATUS' I_CALLBACK_USER_COMMAND = 'USER_COMMAND' IT_EXCLUDING = EXTAB[] I_GRID_TITLE = ALV_TITLE IT_FIELDCAT = FIELDCAT[] TABLES T_OUTTAB = ANNEX_I EXCEPTIONS PROGRAM_ERROR = 1 OTHERS = 2.
REUSE_ALV_FIELDCATALOG_MERGE CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE' EXPORTING I_PROGRAM_NAME = 'HINCF24Q' I_INTERNAL_TABNAME = 'ANNEX_I_NEW' I_INCLNAME = 'PC24QIN2' "RDP 07.05.2005
REUSE_ALV_GRID_DISPLAY CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY' EXPORTING I_CALLBACK_PROGRAM = REPID I_CALLBACK_PF_STATUS_SET = 'SET_PF_STATUS' I_CALLBACK_USER_COMMAND = 'USER_COMMAND' IT_EXCLUDING = EXTAB[] I_GRID_TITLE = ALV_TITLE IT_FIELDCAT = FIELDCAT[] TABLES T_OUTTAB = ANNEX_I_NEW EXCEPTIONS PROGRAM_ERROR = 1 OTHERS = 2.
REUSE_ALV_FIELDCATALOG_MERGE CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE' EXPORTING I_PROGRAM_NAME = 'HINCF24Q' I_INTERNAL_TABNAME = 'ANNEX_II' I_INCLNAME = 'PC24QIN2' CHANGING CT_FIELDCAT = FIELDCAT[] EXCEPTIONS INCONSISTENT_INTERFACE = 1 PROGRAM_ERROR = 2 OTHERS = 3.
REUSE_ALV_GRID_DISPLAY CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY' EXPORTING I_CALLBACK_PROGRAM = REPID I_CALLBACK_PF_STATUS_SET = 'SET_PF_STATUS' I_CALLBACK_USER_COMMAND = 'USER_COMMAND' IT_EXCLUDING = EXTAB[] I_GRID_TITLE = ALV_TITLE IT_FIELDCAT = FIELDCAT[] TABLES T_OUTTAB = ANNEX_II EXCEPTIONS PROGRAM_ERROR = 1 OTHERS = 2.
REUSE_ALV_FIELDCATALOG_MERGE CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE' EXPORTING I_PROGRAM_NAME = 'HINCF24Q' I_INTERNAL_TABNAME = 'NX_TAB_TEMP' I_INCLNAME = 'PC24QIN2' CHANGING CT_FIELDCAT = FIELDCAT[] EXCEPTIONS INCONSISTENT_INTERFACE = 1 PROGRAM_ERROR = 2 OTHERS = 3.
REUSE_ALV_GRID_DISPLAY CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY' EXPORTING I_CALLBACK_PROGRAM = REPID I_CALLBACK_PF_STATUS_SET = 'SET_PF_STATUS' I_CALLBACK_USER_COMMAND = 'USER_COMMAND' IT_EXCLUDING = EXTAB[] I_GRID_TITLE = ALV_TITLE IT_FIELDCAT = FIELDCAT[] TABLES T_OUTTAB = NX_TAB_TEMP EXCEPTIONS PROGRAM_ERROR = 1 OTHERS = 2.
REUSE_ALV_FIELDCATALOG_MERGE CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE' EXPORTING I_PROGRAM_NAME = 'HINCF24Q' I_INTERNAL_TABNAME = 'ERROR_TAB' "'HD_TAB1' I_INCLNAME = 'PC24QIN2' CHANGING CT_FIELDCAT = FIELDCAT[] EXCEPTIONS INCONSISTENT_INTERFACE = 1 PROGRAM_ERROR = 2 OTHERS = 3.
REUSE_ALV_GRID_DISPLAY CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY' EXPORTING I_CALLBACK_PROGRAM = REPID I_CALLBACK_PF_STATUS_SET = 'SET_PF_STATUS' I_CALLBACK_USER_COMMAND = 'USER_COMMAND' IT_EXCLUDING = EXTAB[] I_GRID_TITLE = ALV_TITLE IT_FIELDCAT = FIELDCAT[] TABLES T_OUTTAB = ERROR_TAB EXCEPTIONS PROGRAM_ERROR = 1 OTHERS = 2.
HR_PAYROLL_PERIOD_GET CALL FUNCTION 'HR_PAYROLL_PERIOD_GET' EXPORTING DATE = P_TEMP_DEDDATE PAYROLL_AREA = P0001-ABKRS IMPORTING PAYROLL_YEAR = PY_YEAR PAYROLL_PERIOD = PY_PERIOD.
RS_TREE_CONSTRUCT CALL FUNCTION 'RS_TREE_CONSTRUCT' * EXPORTING * INSERT_ID = '000000' * RELATIONSHIP = ' ' * LOG = TABLES NODETAB = NODE_TAB * EXCEPTIONS * TREE_FAILURE = 1 * ID_NOT_FOUND = 2 * WRONG_RELATIONSHIP = 3 * OTHERS = 4 .
RS_TREE_LIST_DISPLAY CALL FUNCTION 'RS_TREE_LIST_DISPLAY' EXPORTING USE_CONTROL = 'L'.
HR_FEATURE_BACKTABLE CALL FUNCTION 'HR_FEATURE_BACKTABLE' EXPORTING FEATURE = '40ECC' STRUC_CONTENT = PME01 KIND_OF_ERROR = '3' TABLES BACK = ECC_TAB * CHANGING * STATUS = EXCEPTIONS DUMMY = 1 * ERROR_OPERATION = 2 * NO_BACKVALUE = 3 * FEATURE_NOT_GENERATED = 4 * INVALID_SIGN_IN_FUNID = 5 * TAB_IN_REPORT_FIELD_IN_PE03 = 6 OTHERS = 0 .
CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE' EXPORTING I_PROGRAM_NAME = 'HINCF24Q' I_INTERNAL_TABNAME = 'ANNEX_II_NEW' I_INCLNAME = 'PC24QIN2' CHANGING CT_FIELDCAT = FIELDCAT[] EXCEPTIONS INCONSISTENT_INTERFACE = 1 PROGRAM_ERROR = 2 OTHERS = 3.
REUSE_ALV_GRID_DISPLAY CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY' EXPORTING I_CALLBACK_PROGRAM = REPID I_CALLBACK_PF_STATUS_SET = 'SET_PF_STATUS' I_CALLBACK_USER_COMMAND = 'USER_COMMAND' IT_EXCLUDING = EXTAB[] I_GRID_TITLE = ALV_TITLE IT_FIELDCAT = FIELDCAT[] TABLES T_OUTTAB = ANNEX_II_NEW EXCEPTIONS PROGRAM_ERROR = 1 OTHERS = 2.
Although this basic information may have limited use it does provide an easy to find location to store any knowledge about this program/report.
The contribute/comments section below therefore offer's an opportunity for anyone to add additional information. This can be anything from useful hints, tips and screen shots to relevant SAP notes or anything else you feel is relevant to this report.