BCALV_TEST_LIST_FIELDS is a standard Executable ABAP Report available within your SAP system (depending on your version and release level). Below is the basic information available for this SAP report including which OBJECTS it interacts with such as TABLES, FUNCTION MODULES, INCLUDES ETC. Also check out the submitted Comments related to this SAP report or see any standard documentation available.
If you would like to execute this report or see the full code listing simply enter BCALV_TEST_LIST_FIELDS into the relevant SAP transactions such as SE38 or SE80
This report can be called from another progam/report simply by using the ABAP SUBMIT statement, see below for example ABAP code snipts of how to do this.
Selection Text: P_AMOUNT = Number of Records to Be Read
Selection Text: P_DBINFO = DB Info Only (Impr. Perform.)
Title: Program BCALV_TEST_LIST_FIELDS
No INCLUDES are used within this REPORT code!
No SAP DATABASE tables are accessed within this REPORT code!
REUSE_ALV_LIST_DISPLAY call function 'REUSE_ALV_LIST_DISPLAY' exporting * I_INTERFACE_CHECK = ' ' i_bypassing_buffer = gs_test-bypassing_buffer i_buffer_active = gs_test-buffer_active i_callback_program = g_repid i_callback_pf_status_set = 'F01_ALV_EVENT_PF_STATUS_SET' i_callback_user_command = 'F01_ALV_EVENT_USER_COMMAND' * I_STRUCTURE_NAME = is_layout = ls_layo it_fieldcat = lt_fcat * IT_EXCLUDING = * IT_SPECIAL_GROUPS = * IT_SORT = * IT_FILTER = * IS_SEL_HIDE = i_default = l_default i_save = l_save is_variant = ls_vari * IT_EVENTS = * IT_EVENT_EXIT = * IS_PRINT = * IS_REPREP_ID = * I_SCREEN_START_COLUMN = 0 * I_SCREEN_START_LINE = 0 * I_SCREEN_END_COLUMN = 0 * I_SCREEN_END_LINE = 0 * IMPORTING * E_EXIT_CAUSED_BY_CALLER = * ES_EXIT_CAUSED_BY_USER = tables t_outtab = gt_outtab exceptions program_error = 1 others = 2.
REUSE_ALV_FIELDCATALOG_MERGE call function 'REUSE_ALV_FIELDCATALOG_MERGE' exporting * I_PROGRAM_NAME = * i_internal_tabname = i_structure_name = con_sflight * I_CLIENT_NEVER_DISPLAY = 'X' * I_INCLNAME = i_bypassing_buffer = gs_test-bypassing_buffer i_buffer_active = gs_test-buffer_active changing ct_fieldcat = ct_fcat exceptions inconsistent_interface = 1 program_error = 2 others = 3.
REUSE_ALV_LIST_LAYOUT_INFO_GET call function 'REUSE_ALV_LIST_LAYOUT_INFO_GET' importing es_layout = ls_slis_layo et_fieldcat = lt_slis_fcat et_sort = lt_slis_sort et_filter = lt_slis_filt es_variant = ls_vari exceptions no_infos = 1 program_error = 2 others = 3.
REUSE_ALV_GRID_LAYOUT_INFO_GET call function 'REUSE_ALV_GRID_LAYOUT_INFO_GET' importing es_layout = ls_slis_layo et_fieldcat = lt_slis_fcat et_sort = lt_slis_sort et_filter = lt_slis_filt es_variant = ls_vari es_print = ls_slis_prnt exceptions no_infos = 1 program_error = 2 others = 3.
LVC_TRANSFER_FROM_SLIS call function 'LVC_TRANSFER_FROM_SLIS' exporting it_fieldcat_alv = lt_slis_fcat it_sort_alv = lt_slis_sort it_filter_alv = lt_slis_filt is_layout_alv = ls_slis_layo importing et_fieldcat_lvc = lt_lvc_fcat et_sort_lvc = lt_lvc_sort et_filter_lvc = lt_lvc_filt es_layout_lvc = ls_lvc_layo tables it_data = gt_outtab exceptions it_data_missing = 1 others = 2.
LVC_TRANSFER_TO_SLIS call function 'LVC_TRANSFER_TO_SLIS' exporting it_fieldcat_lvc = lt_lvc_fcat it_sort_lvc = lt_lvc_sort it_filter_lvc = lt_lvc_filt is_layout_lvc = ls_lvc_layo importing et_fieldcat_alv = lt_slis_fcat et_sort_alv = lt_slis_sort et_filter_alv = lt_slis_filt es_layout_alv = ls_slis_layo tables it_data = gt_outtab exceptions it_data_missing = 1 it_fieldcat_lvc_missing = 2 others = 3.
REUSE_ALV_LIST_DISPLAY call function 'REUSE_ALV_LIST_DISPLAY' exporting i_bypassing_buffer = gs_test-bypassing_buffer i_buffer_active = gs_test-buffer_active i_callback_program = g_repid i_callback_pf_status_set = 'F01_ALV_EVENT_PF_STATUS_SET' i_callback_user_command = 'F01_ALV_EVENT_USER_COMMAND' is_layout = ls_slis_layo it_fieldcat = lt_slis_fcat it_sort = lt_slis_sort it_filter = lt_slis_filt i_default = gs_test-vari_default i_save = gs_test-vari_save is_variant = ls_vari is_print = ls_slis_prnt tables t_outtab = gt_outtab exceptions program_error = 1 others = 2.
REUSE_ALV_GRID_DISPLAY call function 'REUSE_ALV_GRID_DISPLAY' exporting i_bypassing_buffer = gs_test-bypassing_buffer i_buffer_active = gs_test-buffer_active i_callback_program = g_repid i_callback_pf_status_set = 'F01_ALV_EVENT_PF_STATUS_SET' i_callback_user_command = 'F01_ALV_EVENT_USER_COMMAND' is_layout = ls_slis_layo it_fieldcat = lt_slis_fcat it_sort = lt_slis_sort it_filter = lt_slis_filt i_default = gs_test-vari_default i_save = gs_test-vari_save is_variant = ls_vari is_print = ls_slis_prnt tables t_outtab = gt_outtab exceptions program_error = 1 others = 2.
Although this basic information may have limited use it does provide an easy to find location to store any knowledge about this program/report.
BCALV_TEST_LIST_FIELDS - Program BCALV_TEST_LIST_FIELDS BCALV_TEST_LIST_FIELDS - Program BCALV_TEST_LIST_FIELDS BCALV_TEST_LIST_EVENTS2 - Program BCALV_TEST_LIST_EVENTS2 BCALV_TEST_LIST_EVENTS2 - Program BCALV_TEST_LIST_EVENTS2 BCALV_TEST_LIST_EVENTS - Program BCALV_TEST_LIST_EVENTS BCALV_TEST_LIST_EVENTS - Program BCALV_TEST_LIST_EVENTS