SAP Function Modules

RH_PM_CONVERSION_MAINT SAP Function module







RH_PM_CONVERSION_MAINT is a standard SAP function module available within R/3 SAP systems depending on your version and release level. Below is the pattern details for this FM showing its interface including any import and export parameters, exceptions etc as well as any documentation contributions (Comments) specific to the object.

See here to view full function module documentation and code listing, simply by entering the name RH_PM_CONVERSION_MAINT into the relevant SAP transaction such as SE37 or SE80.

Associated Function Group: RHB8
Released Date: Not Released
Processing type: Normal fucntion module
Normal function module settings


Pattern for FM RH_PM_CONVERSION_MAINT - RH PM CONVERSION MAINT





CALL FUNCTION 'RH_PM_CONVERSION_MAINT' "
  EXPORTING
    plvar =                     " p1506-plvar
*   otype = 'BU'                " p1506-otype
    objid =                     " p1506-objid
*   subty =                     " p1506-subty
*   begda = '19000101'          " p1506-begda
*   endda = '99991231'          " p1506-endda
*   istat = '1'                 " p1506-istat
*   maint = 'DISP'              " t77fc-fcode
*   vtask = 'B'                 " hrrhap-vtask
*   only_converted =            " p1000-histo
* TABLES
*   p1506_tab =                 " p1506
*   conv_father_tab =           " plogi
  EXCEPTIONS
    OTYPE_NOT_VALID = 1         "
    NO_ACTIVE_PLVAR = 2         "
    OBJECT_NOT_FOUND = 3        "
    ERROR_IN_ENQUEUE = 4        "
    INVALID_BUDGET_TYPE = 5     "
    NOTHING_FOUND = 6           "
    NO_CONVERT = 7              "
    CANCEL = 8                  "
    .  "  RH_PM_CONVERSION_MAINT

ABAP code example for Function Module RH_PM_CONVERSION_MAINT





The ABAP code below is a full code listing to execute function module RH_PM_CONVERSION_MAINT including all data declarations. The code uses the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the original method of declaring data variables up front. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8).

DATA:
it_p1506_tab  TYPE STANDARD TABLE OF P1506,"TABLES PARAM
wa_p1506_tab  LIKE LINE OF it_p1506_tab ,
it_conv_father_tab  TYPE STANDARD TABLE OF PLOGI,"TABLES PARAM
wa_conv_father_tab  LIKE LINE OF it_conv_father_tab .


DATA(ld_plvar) = some text here

DATA(ld_otype) = some text here

DATA(ld_objid) = Check type of data required

DATA(ld_subty) = some text here

DATA(ld_begda) = 20210129

DATA(ld_endda) = 20210129

DATA(ld_istat) = some text here

SELECT single FCODE
FROM T77FC
INTO @DATA(ld_maint).


DATA(ld_vtask) = some text here

DATA(ld_only_converted) = some text here

"populate fields of struture and append to itab
append wa_p1506_tab to it_p1506_tab.

"populate fields of struture and append to itab
append wa_conv_father_tab to it_conv_father_tab. . CALL FUNCTION 'RH_PM_CONVERSION_MAINT' EXPORTING plvar = ld_plvar * otype = ld_otype objid = ld_objid * subty = ld_subty * begda = ld_begda * endda = ld_endda * istat = ld_istat * maint = ld_maint * vtask = ld_vtask * only_converted = ld_only_converted * TABLES * p1506_tab = it_p1506_tab * conv_father_tab = it_conv_father_tab EXCEPTIONS OTYPE_NOT_VALID = 1 NO_ACTIVE_PLVAR = 2 OBJECT_NOT_FOUND = 3 ERROR_IN_ENQUEUE = 4 INVALID_BUDGET_TYPE = 5 NOTHING_FOUND = 6 NO_CONVERT = 7 CANCEL = 8 . " RH_PM_CONVERSION_MAINT
IF SY-SUBRC EQ 0. "All OK ELSEIF SY-SUBRC EQ 1. "Exception "Add code for exception here ELSEIF SY-SUBRC EQ 2. "Exception "Add code for exception here ELSEIF SY-SUBRC EQ 3. "Exception "Add code for exception here ELSEIF SY-SUBRC EQ 4. "Exception "Add code for exception here ELSEIF SY-SUBRC EQ 5. "Exception "Add code for exception here ELSEIF SY-SUBRC EQ 6. "Exception "Add code for exception here ELSEIF SY-SUBRC EQ 7. "Exception "Add code for exception here ELSEIF SY-SUBRC EQ 8. "Exception "Add code for exception here ENDIF.







ABAP code to compare 7.40 inline data declaration with original syntax

The below ABAP code uses the older none in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. It may also be useful if you are using an older version of SAP as some of the newer syntax above, such as the @DATA is not available until 4.70 EHP 8.

DATA:
ld_plvar  TYPE P1506-PLVAR ,
it_p1506_tab  TYPE STANDARD TABLE OF P1506 ,
wa_p1506_tab  LIKE LINE OF it_p1506_tab,
ld_otype  TYPE P1506-OTYPE ,
it_conv_father_tab  TYPE STANDARD TABLE OF PLOGI ,
wa_conv_father_tab  LIKE LINE OF it_conv_father_tab,
ld_objid  TYPE P1506-OBJID ,
ld_subty  TYPE P1506-SUBTY ,
ld_begda  TYPE P1506-BEGDA ,
ld_endda  TYPE P1506-ENDDA ,
ld_istat  TYPE P1506-ISTAT ,
ld_maint  TYPE T77FC-FCODE ,
ld_vtask  TYPE HRRHAP-VTASK ,
ld_only_converted  TYPE P1000-HISTO .


ld_plvar = some text here

"populate fields of struture and append to itab
append wa_p1506_tab to it_p1506_tab.

ld_otype = some text here

"populate fields of struture and append to itab
append wa_conv_father_tab to it_conv_father_tab.

ld_objid = Check type of data required

ld_subty = some text here

ld_begda = 20210129

ld_endda = 20210129

ld_istat = some text here

SELECT single FCODE
FROM T77FC
INTO ld_maint.


ld_vtask = some text here

ld_only_converted = some text here

Contribute (Add Comments)

Please help keep this info upto date and use the comments section below to add useful hints, tips and information specific to this SAP function. This will then be available for you and other users to easily find by simply searching on the object name RH_PM_CONVERSION_MAINT or its description.