HR_CH_RESET_CUMU_SV is a standard SAP function module available within R/3 SAP systems depending on your version and release level. Below is the pattern details for this FM showing its interface including any import and export parameters, exceptions etc as well as any documentation contributions (Comments) specific to the object.
See here to view full function module documentation and code listing, simply by entering the name HR_CH_RESET_CUMU_SV into the relevant SAP transaction such as SE37 or SE80.
Associated Function Group:
RPCI
Released Date:
Not Released
Processing type: Normal fucntion module
CALL FUNCTION 'HR_CH_RESET_CUMU_SV' "
EXPORTING
p02_anwschl = " p02_anwsch
p02_stichtag = " endda
* p02_outtab = " t5cs3-out_tab
p02_sv = " pc20u
p02_mosv = " t5cs1-mosv
p02_loekz = " pch03_kennz
* p02_prot = " c
* TABLES
* p02_ptext = " plog_text
* p02_error = " plog_text
CHANGING
p02_abrdat = " pch03_abrdat
. " HR_CH_RESET_CUMU_SV
The ABAP code below is a full code listing to execute function module HR_CH_RESET_CUMU_SV including all data declarations. The code uses the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the original method of declaring data variables up front. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8).
| it_p02_ptext | TYPE STANDARD TABLE OF PLOG_TEXT,"TABLES PARAM |
| wa_p02_ptext | LIKE LINE OF it_p02_ptext , |
| it_p02_error | TYPE STANDARD TABLE OF PLOG_TEXT,"TABLES PARAM |
| wa_p02_error | LIKE LINE OF it_p02_error . |
The below ABAP code uses the older none in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. It may also be useful if you are using an older version of SAP as some of the newer syntax above, such as the @DATA is not available until 4.70 EHP 8.
DATA:
| ld_p02_abrdat | TYPE PCH03_ABRDAT , |
| ld_p02_anwschl | TYPE P02_ANWSCH , |
| it_p02_ptext | TYPE STANDARD TABLE OF PLOG_TEXT , |
| wa_p02_ptext | LIKE LINE OF it_p02_ptext, |
| ld_p02_stichtag | TYPE ENDDA , |
| it_p02_error | TYPE STANDARD TABLE OF PLOG_TEXT , |
| wa_p02_error | LIKE LINE OF it_p02_error, |
| ld_p02_outtab | TYPE T5CS3-OUT_TAB , |
| ld_p02_sv | TYPE PC20U , |
| ld_p02_mosv | TYPE T5CS1-MOSV , |
| ld_p02_loekz | TYPE PCH03_KENNZ , |
| ld_p02_prot | TYPE C . |
Please help keep this info upto date and use the comments section below to add useful hints, tips and information specific to this SAP function. This will then be available for you and other users to easily find by simply searching on the object name HR_CH_RESET_CUMU_SV or its description.