SAP S073 ABAP Select data from SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP S073 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to S073. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the S073 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_S073 TYPE STANDARD TABLE OF S073,
WA_S073 TYPE S073,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <S073> TYPE S073.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_S073.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM S073
INTO TABLE IT_S073.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM S073
* INTO TABLE @DATA(IT_S0732).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_S073 INDEX 1 INTO DATA(WA_S0732).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_S073 ASSIGNING <S073>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<S073>-MANDT = 1.
<S073>-SSOUR = 1.
<S073>-VRSIO = 1.
<S073>-VGBEL = 1.
<S073>-VGPOS = 1.
ENDLOOP. LOOP AT IT_S073 INTO WA_S073. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_S073-SPMON, sy-vline,
WA_S073-SPTAG, sy-vline,
WA_S073-SPWOC, sy-vline,
WA_S073-SPBUP, sy-vline,
WA_S073-PERIV, sy-vline,
WA_S073-VWDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_S073 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_S073 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_S073 INTO WA_S073. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field VGBEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_S073-VGBEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S073-VGBEL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit PERI, internal->external for field SPMON CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_S073-SPMON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S073-SPMON.
WRITE:/ 'New Value:', ld_input.
*Conversion exit PERI, internal->external for field SPWOC CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_S073-SPWOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S073-SPWOC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit PERI, internal->external for field SPBUP CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_S073-SPBUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S073-SPBUP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field BASME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_S073-BASME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_S073-BASME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_S073_STR,
MANDT TYPE STRING,
SSOUR TYPE STRING,
VRSIO TYPE STRING,
VGBEL TYPE STRING,
VGPOS TYPE STRING,
SPMON TYPE STRING,
SPTAG TYPE STRING,
SPWOC TYPE STRING,
SPBUP TYPE STRING,
PERIV TYPE STRING,
VWDAT TYPE STRING,
BASME TYPE STRING,
LIEFFZ TYPE STRING,
ENTNFZ TYPE STRING,
WAGFZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_S073_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_S073_STR-MANDT sy-vline
WA_S073_STR-SSOUR sy-vline
WA_S073_STR-VRSIO sy-vline
WA_S073_STR-VGBEL sy-vline
WA_S073_STR-VGPOS sy-vline
WA_S073_STR-SPMON sy-vline
WA_S073_STR-SPTAG sy-vline
WA_S073_STR-SPWOC sy-vline
WA_S073_STR-SPBUP sy-vline
WA_S073_STR-PERIV sy-vline
WA_S073_STR-VWDAT sy-vline
WA_S073_STR-BASME sy-vline
WA_S073_STR-LIEFFZ sy-vline
WA_S073_STR-ENTNFZ sy-vline
WA_S073_STR-WAGFZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.
Search for further information about these or an SAP related objects