SAP DACH_D_TIMEDATA ABAP Select data from SAP table









Below is a number of ABAP code snippets to demonstrate how to select data from SAP DACH_D_TIMEDATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DACH_D_TIMEDATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DACH_D_TIMEDATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DACH_D_TIMEDATA TYPE STANDARD TABLE OF DACH_D_TIMEDATA,
      WA_DACH_D_TIMEDATA TYPE DACH_D_TIMEDATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DACH_D_TIMEDATA> TYPE DACH_D_TIMEDATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DACH_D_TIMEDATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DACH_D_TIMEDATA
  INTO TABLE IT_DACH_D_TIMEDATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DACH_D_TIMEDATA
*  INTO TABLE @DATA(IT_DACH_D_TIMEDATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DACH_D_TIMEDATA INDEX 1 INTO DATA(WA_DACH_D_TIMEDATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DACH_D_TIMEDATA ASSIGNING <DACH_D_TIMEDATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DACH_D_TIMEDATA>-CLIENT = 1.
<DACH_D_TIMEDATA>-PERNR = 1.
<DACH_D_TIMEDATA>-INFTY = 1.
<DACH_D_TIMEDATA>-SUBTY = 1.
<DACH_D_TIMEDATA>-OBJPS = 1.
ENDLOOP.

LOOP AT IT_DACH_D_TIMEDATA INTO WA_DACH_D_TIMEDATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DACH_D_TIMEDATA-SPRPS, sy-vline,
WA_DACH_D_TIMEDATA-ENDDA, sy-vline,
WA_DACH_D_TIMEDATA-BEGDA, sy-vline,
WA_DACH_D_TIMEDATA-SEQNR, sy-vline,
WA_DACH_D_TIMEDATA-DOCUMENT_TYPE, sy-vline,
WA_DACH_D_TIMEDATA-ACTION_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DACH_D_TIMEDATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DACH_D_TIMEDATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DACH_D_TIMEDATA INTO WA_DACH_D_TIMEDATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DACH_D_TIMEDATA_STR,
CLIENT TYPE STRING,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
DOCUMENT_TYPE TYPE STRING,
ACTION_TYPE TYPE STRING,
INSTANCE_COUNT TYPE STRING,
DAC_PP_COMPONENT TYPE STRING,
DAC_INDIRECT_ACCESS TYPE STRING,
DAC_CREATION_DATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_DACH_D_TIMEDATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DACH_D_TIMEDATA_STR-CLIENT sy-vline
WA_DACH_D_TIMEDATA_STR-PERNR sy-vline
WA_DACH_D_TIMEDATA_STR-INFTY sy-vline
WA_DACH_D_TIMEDATA_STR-SUBTY sy-vline
WA_DACH_D_TIMEDATA_STR-OBJPS sy-vline
WA_DACH_D_TIMEDATA_STR-SPRPS sy-vline
WA_DACH_D_TIMEDATA_STR-ENDDA sy-vline
WA_DACH_D_TIMEDATA_STR-BEGDA sy-vline
WA_DACH_D_TIMEDATA_STR-SEQNR sy-vline
WA_DACH_D_TIMEDATA_STR-DOCUMENT_TYPE sy-vline
WA_DACH_D_TIMEDATA_STR-ACTION_TYPE sy-vline
WA_DACH_D_TIMEDATA_STR-INSTANCE_COUNT sy-vline
WA_DACH_D_TIMEDATA_STR-DAC_PP_COMPONENT sy-vline
WA_DACH_D_TIMEDATA_STR-DAC_INDIRECT_ACCESS sy-vline
WA_DACH_D_TIMEDATA_STR-DAC_CREATION_DATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.


Search for further information about these or an SAP related objects



Comments on this SAP object

What made you want to lookup this SAP object? Please tell us what you were looking for and anything you would like to be included on this page!