SAP RSD_IOBC_MULTI_GET Function Module for Read one or more InfoObjectCatalogs with InfoObjects
RSD_IOBC_MULTI_GET is a standard rsd iobc multi get SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used for Read one or more InfoObjectCatalogs with InfoObjects processing and below is the pattern details for this FM, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.
See here to view full function module documentation and code listing for rsd iobc multi get FM, simply by entering the name RSD_IOBC_MULTI_GET into the relevant SAP transaction such as SE37 or SE38.
Function Group: RSDG_IOBC_DB_READ
Program Name: SAPLRSDG_IOBC_DB_READ
Main Program: SAPLRSDG_IOBC_DB_READ
Appliation area:
Release date: N/A
Mode(Normal, Remote etc): Normal Function Module
Update:

Function RSD_IOBC_MULTI_GET pattern details
In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.CALL FUNCTION 'RSD_IOBC_MULTI_GET'"Read one or more InfoObjectCatalogs with InfoObjects.
EXPORTING
* I_READ_ALL = RS_C_FALSE "All Catalogs, all for InfoArea resp.
* I_OBJVERS = RS_C_OBJVERS-ACTIVE "Version
* I_BYPASS_BUFFER = RS_C_FALSE "Bypass and Refresh Buffer (Indicator)
* I_WITH_MESSAGE = RS_C_TRUE "With Message
IMPORTING
E_NOT_ALL_OBJ_READ = "Not All Objects Read (Indicator)
E_T_VCHA = "Characteristics (Ordered)
E_T_KYF = "Key Figures (Ordered)
E_T_VIOBJ = "View of All InfoObject Types
E_T_IOBJ_CMP = "Compounding (Filled Only If Occupied; Ordered)
E_T_ATR = "Attributes (Filled Only If Occupied; Ordered)
E_T_IOBC = "List of read InfoObjectCatalogs
E_T_IOBC_IOBJ = "InfoObjects per InfoObjectCatalog
E_T_IOBCT = "InfoObjectCatalogue texts
CHANGING
* C_INFOAREA = RS_C_' '30 "Name of InfoArea (or *)
* C_INFOOBJCAT = RS_C_' '30 "Name of InfoObjCatalogs (or *)
EXCEPTIONS
INFOOBJCAT_NOT_FOUND = 1 ILLEGAL_INPUT = 2
IMPORTING Parameters details for RSD_IOBC_MULTI_GET
I_READ_ALL - All Catalogs, all for InfoArea resp.
Data type: RS_BOOLDefault: RS_C_FALSE
Optional: Yes
Call by Reference: No ( called with pass by value option)
I_OBJVERS - Version
Data type: RS_OBJVERSDefault: RS_C_OBJVERS-ACTIVE
Optional: Yes
Call by Reference: No ( called with pass by value option)
I_BYPASS_BUFFER - Bypass and Refresh Buffer (Indicator)
Data type: RS_BOOLDefault: RS_C_FALSE
Optional: Yes
Call by Reference: No ( called with pass by value option)
I_WITH_MESSAGE - With Message
Data type: RS_BOOLDefault: RS_C_TRUE
Optional: Yes
Call by Reference: No ( called with pass by value option)
EXPORTING Parameters details for RSD_IOBC_MULTI_GET
E_NOT_ALL_OBJ_READ - Not All Objects Read (Indicator)
Data type: RS_BOOLOptional: No
Call by Reference: Yes
E_T_VCHA - Characteristics (Ordered)
Data type: RSD_T_VCHAOptional: No
Call by Reference: Yes
E_T_KYF - Key Figures (Ordered)
Data type: RSD_T_KYFOptional: No
Call by Reference: Yes
E_T_VIOBJ - View of All InfoObject Types
Data type: RSD_T_VIOBJOptional: No
Call by Reference: Yes
E_T_IOBJ_CMP - Compounding (Filled Only If Occupied; Ordered)
Data type: RSD_T_IOBJ_CMPOptional: No
Call by Reference: Yes
E_T_ATR - Attributes (Filled Only If Occupied; Ordered)
Data type: RSD_T_ATROptional: No
Call by Reference: Yes
E_T_IOBC - List of read InfoObjectCatalogs
Data type: RSD_T_IOBCOptional: No
Call by Reference: Yes
E_T_IOBC_IOBJ - InfoObjects per InfoObjectCatalog
Data type: RSD_T_IOBC_IOBJOptional: No
Call by Reference: Yes
E_T_IOBCT - InfoObjectCatalogue texts
Data type: RSD_T_IOBCTOptional: No
Call by Reference: Yes
CHANGING Parameters details for RSD_IOBC_MULTI_GET
C_INFOAREA - Name of InfoArea (or *)
Data type: RSD_INFOAREADefault: RS_C_SPACE30
Optional: Yes
Call by Reference: Yes
C_INFOOBJCAT - Name of InfoObjCatalogs (or *)
Data type: RSD_INFOOBJCATDefault: RS_C_SPACE30
Optional: Yes
Call by Reference: Yes
EXCEPTIONS details
INFOOBJCAT_NOT_FOUND - InfoObjCat not found
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
ILLEGAL_INPUT - Invalid Entry
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
Copy and paste ABAP code example for RSD_IOBC_MULTI_GET Function Module
The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.| DATA: | ||||
| lv_c_infoarea | TYPE RSD_INFOAREA, " RS_C_SPACE30 | |||
| lv_i_read_all | TYPE RS_BOOL, " RS_C_FALSE | |||
| lv_e_not_all_obj_read | TYPE RS_BOOL, " | |||
| lv_infoobjcat_not_found | TYPE RS_BOOL, " | |||
| lv_e_t_vcha | TYPE RSD_T_VCHA, " | |||
| lv_i_objvers | TYPE RS_OBJVERS, " RS_C_OBJVERS-ACTIVE | |||
| lv_c_infoobjcat | TYPE RSD_INFOOBJCAT, " RS_C_SPACE30 | |||
| lv_illegal_input | TYPE RSD_INFOOBJCAT, " | |||
| lv_e_t_kyf | TYPE RSD_T_KYF, " | |||
| lv_i_bypass_buffer | TYPE RS_BOOL, " RS_C_FALSE | |||
| lv_e_t_viobj | TYPE RSD_T_VIOBJ, " | |||
| lv_i_with_message | TYPE RS_BOOL, " RS_C_TRUE | |||
| lv_e_t_iobj_cmp | TYPE RSD_T_IOBJ_CMP, " | |||
| lv_e_t_atr | TYPE RSD_T_ATR, " | |||
| lv_e_t_iobc | TYPE RSD_T_IOBC, " | |||
| lv_e_t_iobc_iobj | TYPE RSD_T_IOBC_IOBJ, " | |||
| lv_e_t_iobct | TYPE RSD_T_IOBCT. " |
|   CALL FUNCTION 'RSD_IOBC_MULTI_GET' "Read one or more InfoObjectCatalogs with InfoObjects |
| EXPORTING | ||
| I_READ_ALL | = lv_i_read_all | |
| I_OBJVERS | = lv_i_objvers | |
| I_BYPASS_BUFFER | = lv_i_bypass_buffer | |
| I_WITH_MESSAGE | = lv_i_with_message | |
| IMPORTING | ||
| E_NOT_ALL_OBJ_READ | = lv_e_not_all_obj_read | |
| E_T_VCHA | = lv_e_t_vcha | |
| E_T_KYF | = lv_e_t_kyf | |
| E_T_VIOBJ | = lv_e_t_viobj | |
| E_T_IOBJ_CMP | = lv_e_t_iobj_cmp | |
| E_T_ATR | = lv_e_t_atr | |
| E_T_IOBC | = lv_e_t_iobc | |
| E_T_IOBC_IOBJ | = lv_e_t_iobc_iobj | |
| E_T_IOBCT | = lv_e_t_iobct | |
| CHANGING | ||
| C_INFOAREA | = lv_c_infoarea | |
| C_INFOOBJCAT | = lv_c_infoobjcat | |
| EXCEPTIONS | ||
| INFOOBJCAT_NOT_FOUND = 1 | ||
| ILLEGAL_INPUT = 2 | ||
| . " RSD_IOBC_MULTI_GET | ||
ABAP code using 7.40 inline data declarations to call FM RSD_IOBC_MULTI_GET
The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.| DATA(ld_c_infoarea) | = RS_C_' '30. | |||
| DATA(ld_i_read_all) | = RS_C_FALSE. | |||
| DATA(ld_i_objvers) | = RS_C_OBJVERS-ACTIVE. | |||
| DATA(ld_c_infoobjcat) | = RS_C_' '30. | |||
| DATA(ld_i_bypass_buffer) | = RS_C_FALSE. | |||
| DATA(ld_i_with_message) | = RS_C_TRUE. | |||
Search for further information about these or an SAP related objects