SAP ISU_S_DEVICERATE_CHANGE Function Module for INTERNAL: Maintain Rate Data of Device









ISU_S_DEVICERATE_CHANGE is a standard isu s devicerate change SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used for INTERNAL: Maintain Rate Data of Device processing and below is the pattern details for this FM, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.


See here to view full function module documentation and code listing for isu s devicerate change FM, simply by entering the name ISU_S_DEVICERATE_CHANGE into the relevant SAP transaction such as SE37 or SE38.

Function Group: EG70
Program Name: SAPLEG70
Main Program: SAPLEG70
Appliation area: E
Release date: N/A
Mode(Normal, Remote etc): Normal Function Module
Update:



Function ISU_S_DEVICERATE_CHANGE pattern details

In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.
CALL FUNCTION 'ISU_S_DEVICERATE_CHANGE'"INTERNAL: Maintain Rate Data of Device
EXPORTING
* X_ANLAGE = "
* X_NO_DIALOG = "Indicator: no dialog
* X_AUTO = "Automation data
* X_OBJ = "Object Data (From Previous OPEN Call)
* X_NO_OTHER = "
* X_NO_ENTRY_CHECK = ' ' "
* X_NO_UPDATE = ' ' "
* X_PRORATE_TIME_TAB = "
* X_CRM_RELATED = ' ' "Indicator
* X_HISTORY = ' ' "Display/Change ISU History
* X_GERAET = "
* X_GERTYP = "
* X_SPARTEG = "
* X_EQUNR = "Equipment
X_STICHTAG = "
* X_PRORATE = 'X' "
* X_TIMESLICES = "
* X_UPD_ONLINE = 'X' "Indicator: Update Online

IMPORTING
Y_DB_UPDATE = "Indicator: data change
Y_EXIT_TYPE = "Return Mode

CHANGING
* XY_INTEGRATION = "

EXCEPTIONS
NOT_FOUND = 1 FOREIGN_LOCK = 2 CANCELLED = 3 INPUT_ERROR = 4 GENERAL_FAULT = 5
.



IMPORTING Parameters details for ISU_S_DEVICERATE_CHANGE

X_ANLAGE -

Data type: REG70-ANLAGE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_NO_DIALOG - Indicator: no dialog

Data type: REGEN-NO_DIALOG
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_AUTO - Automation data

Data type: ISU70_DEVICERATE_AUTO
Optional: Yes
Call by Reference: Yes

X_OBJ - Object Data (From Previous OPEN Call)

Data type: ISU70_DEVICERATE
Optional: Yes
Call by Reference: Yes

X_NO_OTHER -

Data type: REGEN-NO_OTHER
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_NO_ENTRY_CHECK -

Data type: REGEN-KENNZX
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_NO_UPDATE -

Data type: REGEN-NO_UPDATE
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_PRORATE_TIME_TAB -

Data type: ISU07_TIMEPOINT_TAB
Optional: Yes
Call by Reference: Yes

X_CRM_RELATED - Indicator

Data type: KENNZX
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_HISTORY - Display/Change ISU History

Data type: REGEN-HISTORY
Default: SPACE
Optional: Yes
Call by Reference: Yes

X_GERAET -

Data type: REG70-GERAET
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_GERTYP -

Data type: REG70-GERTYP
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_SPARTEG -

Data type: REG70-SPARTEG
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_EQUNR - Equipment

Data type: REG70-EQUNR
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_STICHTAG -

Data type: REG70-STICHTAG
Optional: No
Call by Reference: No ( called with pass by value option)

X_PRORATE -

Data type: REGEN-KENNZX
Default: 'X'
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_TIMESLICES -

Data type: REGEN-KENNZX
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_UPD_ONLINE - Indicator: Update Online

Data type: REGEN-UPD_ONLINE
Default: 'X'
Optional: Yes
Call by Reference: No ( called with pass by value option)

EXPORTING Parameters details for ISU_S_DEVICERATE_CHANGE

Y_DB_UPDATE - Indicator: data change

Data type: REGEN-DB_UPDATE
Optional: No
Call by Reference: No ( called with pass by value option)

Y_EXIT_TYPE - Return Mode

Data type: REGEN-EXIT_TYPE
Optional: No
Call by Reference: No ( called with pass by value option)

CHANGING Parameters details for ISU_S_DEVICERATE_CHANGE

XY_INTEGRATION -

Data type: ISU07_INTEGRATION_DATA
Optional: Yes
Call by Reference: Yes

EXCEPTIONS details

NOT_FOUND - Object does not exist

Data type:
Optional: No
Call by Reference: No ( called with pass by value option)

FOREIGN_LOCK - Object Currently Locked

Data type:
Optional: No
Call by Reference: No ( called with pass by value option)

CANCELLED -

Data type:
Optional: No
Call by Reference: No ( called with pass by value option)

INPUT_ERROR - Invalid Automation Data

Data type:
Optional: No
Call by Reference: No ( called with pass by value option)

GENERAL_FAULT - Other

Data type:
Optional: No
Call by Reference: No ( called with pass by value option)

Copy and paste ABAP code example for ISU_S_DEVICERATE_CHANGE Function Module

The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.

DATA:
lv_x_anlage  TYPE REG70-ANLAGE, "   
lv_not_found  TYPE REG70, "   
lv_y_db_update  TYPE REGEN-DB_UPDATE, "   
lv_xy_integration  TYPE ISU07_INTEGRATION_DATA, "   
lv_x_no_dialog  TYPE REGEN-NO_DIALOG, "   
lv_x_auto  TYPE ISU70_DEVICERATE_AUTO, "   
lv_x_obj  TYPE ISU70_DEVICERATE, "   
lv_x_no_other  TYPE REGEN-NO_OTHER, "   
lv_x_no_entry_check  TYPE REGEN-KENNZX, "   SPACE
lv_x_no_update  TYPE REGEN-NO_UPDATE, "   SPACE
lv_x_prorate_time_tab  TYPE ISU07_TIMEPOINT_TAB, "   
lv_x_crm_related  TYPE KENNZX, "   SPACE
lv_x_history  TYPE REGEN-HISTORY, "   SPACE
lv_x_geraet  TYPE REG70-GERAET, "   
lv_y_exit_type  TYPE REGEN-EXIT_TYPE, "   
lv_foreign_lock  TYPE REGEN, "   
lv_x_gertyp  TYPE REG70-GERTYP, "   
lv_cancelled  TYPE REG70, "   
lv_x_sparteg  TYPE REG70-SPARTEG, "   
lv_input_error  TYPE REG70, "   
lv_x_equnr  TYPE REG70-EQUNR, "   
lv_general_fault  TYPE REG70, "   
lv_x_stichtag  TYPE REG70-STICHTAG, "   
lv_x_prorate  TYPE REGEN-KENNZX, "   'X'
lv_x_timeslices  TYPE REGEN-KENNZX, "   
lv_x_upd_online  TYPE REGEN-UPD_ONLINE. "   'X'

  CALL FUNCTION 'ISU_S_DEVICERATE_CHANGE'  "INTERNAL: Maintain Rate Data of Device
    EXPORTING
         X_ANLAGE = lv_x_anlage
         X_NO_DIALOG = lv_x_no_dialog
         X_AUTO = lv_x_auto
         X_OBJ = lv_x_obj
         X_NO_OTHER = lv_x_no_other
         X_NO_ENTRY_CHECK = lv_x_no_entry_check
         X_NO_UPDATE = lv_x_no_update
         X_PRORATE_TIME_TAB = lv_x_prorate_time_tab
         X_CRM_RELATED = lv_x_crm_related
         X_HISTORY = lv_x_history
         X_GERAET = lv_x_geraet
         X_GERTYP = lv_x_gertyp
         X_SPARTEG = lv_x_sparteg
         X_EQUNR = lv_x_equnr
         X_STICHTAG = lv_x_stichtag
         X_PRORATE = lv_x_prorate
         X_TIMESLICES = lv_x_timeslices
         X_UPD_ONLINE = lv_x_upd_online
    IMPORTING
         Y_DB_UPDATE = lv_y_db_update
         Y_EXIT_TYPE = lv_y_exit_type
    CHANGING
         XY_INTEGRATION = lv_xy_integration
    EXCEPTIONS
        NOT_FOUND = 1
        FOREIGN_LOCK = 2
        CANCELLED = 3
        INPUT_ERROR = 4
        GENERAL_FAULT = 5
. " ISU_S_DEVICERATE_CHANGE




ABAP code using 7.40 inline data declarations to call FM ISU_S_DEVICERATE_CHANGE

The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.

"SELECT single ANLAGE FROM REG70 INTO @DATA(ld_x_anlage).
 
 
"SELECT single DB_UPDATE FROM REGEN INTO @DATA(ld_y_db_update).
 
 
"SELECT single NO_DIALOG FROM REGEN INTO @DATA(ld_x_no_dialog).
 
 
 
"SELECT single NO_OTHER FROM REGEN INTO @DATA(ld_x_no_other).
 
"SELECT single KENNZX FROM REGEN INTO @DATA(ld_x_no_entry_check).
DATA(ld_x_no_entry_check) = ' '.
 
"SELECT single NO_UPDATE FROM REGEN INTO @DATA(ld_x_no_update).
DATA(ld_x_no_update) = ' '.
 
 
DATA(ld_x_crm_related) = ' '.
 
"SELECT single HISTORY FROM REGEN INTO @DATA(ld_x_history).
DATA(ld_x_history) = ' '.
 
"SELECT single GERAET FROM REG70 INTO @DATA(ld_x_geraet).
 
"SELECT single EXIT_TYPE FROM REGEN INTO @DATA(ld_y_exit_type).
 
 
"SELECT single GERTYP FROM REG70 INTO @DATA(ld_x_gertyp).
 
 
"SELECT single SPARTEG FROM REG70 INTO @DATA(ld_x_sparteg).
 
 
"SELECT single EQUNR FROM REG70 INTO @DATA(ld_x_equnr).
 
 
"SELECT single STICHTAG FROM REG70 INTO @DATA(ld_x_stichtag).
 
"SELECT single KENNZX FROM REGEN INTO @DATA(ld_x_prorate).
DATA(ld_x_prorate) = 'X'.
 
"SELECT single KENNZX FROM REGEN INTO @DATA(ld_x_timeslices).
 
"SELECT single UPD_ONLINE FROM REGEN INTO @DATA(ld_x_upd_online).
DATA(ld_x_upd_online) = 'X'.
 


Search for further information about these or an SAP related objects



Comments on this SAP object

What made you want to lookup this SAP object? Please tell us what you were looking for and anything you would like to be included on this page!