GET_VALID_PARTS_PER_LOC SAP Method Delivers Valid Parts per Functional Location
Below is documentation, parameters and attributes of ABAP Method GET_VALID_PARTS_PER_LOC within SAP class IF_EX_BADI_MPL_IWB. There is also a number of example ABAP code snipts to help you use the functionality of this method.
This method is available within SAP systems depending on your version and release level, you can view further information by entering the class name IF_EX_BADI_MPL_IWB into the relevant SAP transactions such as SE24 or SE80, and then selecting the method you are interested in.
Method Type - Instance
This is an Instance Method so needs to be instantiated first before you can access any of the methods. I.e. you need to create a local variable of TYPE ref to the class.The following technical details of method GET_VALID_PARTS_PER_LOC can also be found below:
- Importing parameters
- Exporting parameters
- Changing parameters
- Returning parameters
- Exceptions
- Coding Examples
Parameters of Method GET_VALID_PARTS_PER_LOC
.| Name | Type | Data Type | Description | Default Value |
| CANCEL_PART | Importing | TYPE MATNR | old Material number | |
| CHECK_CANCEL_PART | Importing | TYPE XFELD | Checkbox: Check cancel part | |
| CHECK_ONLY_CURRENT_PART | Importing | TYPE XFELD | Checkbox: Check only the current part | |
| CHECK_SETS | Importing | TYPE XFELD | Checkbox: Check set relations | |
| CLINT | Importing | TYPE CLINT | Internal Class Number | |
| CONF_AS_MAINTAINED | Importing | TYPE TT_CCM_TARGET_CONFIG_DETAIL | CCM: Configuration Data for MPL Explosion | |
| CURRENT_PART | Importing | TYPE MATNR | Material number to be checked | |
| EXPL_GUID | Importing | TYPE PVS_GUID | Internal identification for iPPE filter | |
| INIT_ECM | Importing | TYPE XFELD | Flag: init ECM | |
| IR_BADI_CCM_FID | Importing | TYPE REF TO IF_EX_BADI_CCM_FID | ||
| IT_CLINT | Importing | TYPE TT_CCM_CLINT | Table of iPPE product classes used in the MPL explosion | |
| IV_CLINT_TABLE_CHANGED | Importing | TYPE XFELD | ||
| LEVEL | Importing | TYPE BALLEVEL | Application Log: Level of detail | |
| LOG_HANDLE | Importing | TYPE BALLOGHNDL | Application Log: Log handle | |
| MOD_LIST | Importing | TYPE TAB_MPL_MOD_LIST | Table of Mods per PPE Node | |
| PFGUID | Importing | TYPE FOC_GUID | Internal Identification of Focus Record | |
| PNGUID | Importing | TYPE PVS_PNGUID | Node to be investigated | |
| PROBCLASS | Importing | TYPE BALPROBCL | Application log: Message problem class | |
| TECHS | Importing | TYPE TECHS | Parameter variant/standard variant | |
| ALL_PARTS_FOR_NODE | Exporting | TYPE TAB_MPL_MATERIALS_FOR_NODE | All materials for the node | |
| PNODID_TAB | Exporting | TYPE PPET_PNODID_LI_TAB | Attributes of the iPPE nodes | |
| PNODTX_TAB | Exporting | TYPE PPET_PNODTX_LI_TAB | Text attributes of iPPE nodes | |
| VALID_PARTS_FOR_NODE | Exporting | TYPE TAB_MPL_MATERIALS_FOR_NODE | Valid materials for the node | |
| CT_CONF_AS_MAINTAINED | Changing | TYPE TT_CCM_TARGET_CONFIG_DETAIL | CCM: Configuration Data for MPL Explosion | |
| CUOBJ | Changing | TYPE CUOBJ | Configuration (internal object number) |
Exceptions of Method GET_VALID_PARTS_PER_LOC
This method does not have any exceptionsExample ABAP coding
DATA: lo_class TYPE REF TO IF_EX_BADI_MPL_IWB.
DATA: lv_ALL_PARTS_FOR_NODE TYPE TAB_MPL_MATERIALS_FOR_NODE,
lv_CANCEL_PART TYPE MATNR,
lv_CHECK_CANCEL_PART TYPE XFELD,
lv_CHECK_ONLY_CURRENT_PART TYPE XFELD,
lv_CHECK_SETS TYPE XFELD,
lv_CLINT TYPE CLINT,
lv_CONF_AS_MAINTAINED TYPE TT_CCM_TARGET_CONFIG_DETAIL,
lv_CT_CONF_AS_MAINTAINED TYPE TT_CCM_TARGET_CONFIG_DETAIL,
lv_CUOBJ TYPE CUOBJ,
lv_CURRENT_PART TYPE MATNR,
lv_EXPL_GUID TYPE PVS_GUID,
lv_INIT_ECM TYPE XFELD,
lv_IR_BADI_CCM_FID TYPE IF_EX_BADI_CCM_FID,
lv_IT_CLINT TYPE TT_CCM_CLINT,
lv_IV_CLINT_TABLE_CHANGED TYPE XFELD,
lv_LEVEL TYPE BALLEVEL,
lv_LOG_HANDLE TYPE BALLOGHNDL,
lv_MOD_LIST TYPE TAB_MPL_MOD_LIST,
lv_PFGUID TYPE FOC_GUID,
lv_PNGUID TYPE PVS_PNGUID,
lv_PNODID_TAB TYPE PPET_PNODID_LI_TAB,
lv_PNODTX_TAB TYPE PPET_PNODTX_LI_TAB,
lv_PROBCLASS TYPE BALPROBCL,
lv_TECHS TYPE TECHS,
lv_VALID_PARTS_FOR_NODE TYPE TAB_MPL_MATERIALS_FOR_NODE,
lv_other TYPE c.
CALL METHOD lo_class=>GET_VALID_PARTS_PER_LOC(
EXPORTING
CANCEL_PART = lv_CANCEL_PART
CHECK_CANCEL_PART = lv_CHECK_CANCEL_PART
CHECK_ONLY_CURRENT_PART = lv_CHECK_ONLY_CURRENT_PART
CHECK_SETS = lv_CHECK_SETS
CLINT = lv_CLINT
CONF_AS_MAINTAINED = lv_CONF_AS_MAINTAINED
CURRENT_PART = lv_CURRENT_PART
EXPL_GUID = lv_EXPL_GUID
INIT_ECM = lv_INIT_ECM
IR_BADI_CCM_FID = lv_IR_BADI_CCM_FID
IT_CLINT = lv_IT_CLINT
IV_CLINT_TABLE_CHANGED = lv_IV_CLINT_TABLE_CHANGED
LEVEL = lv_LEVEL
LOG_HANDLE = lv_LOG_HANDLE
MOD_LIST = lv_MOD_LIST
PFGUID = lv_PFGUID
PNGUID = lv_PNGUID
PROBCLASS = lv_PROBCLASS
TECHS = lv_TECHS
IMPORTING
ALL_PARTS_FOR_NODE = lv_ALL_PARTS_FOR_NODE
PNODID_TAB = lv_PNODID_TAB
PNODTX_TAB = lv_PNODTX_TAB
VALID_PARTS_FOR_NODE = lv_VALID_PARTS_FOR_NODE
CHANGING
CT_CONF_AS_MAINTAINED = lv_CT_CONF_AS_MAINTAINED
CUOBJ = lv_CUOBJ ).
Links to Related Class(s)
IF_EX_BA...Full list of available SAP object classes
Search for further information about these or an SAP related objects