GET_VALID_PARTS_PER_LOC SAP Method Delivers Valid Parts per Functional Location









Below is documentation, parameters and attributes of ABAP Method GET_VALID_PARTS_PER_LOC within SAP class IF_EX_BADI_MPL_IWB. There is also a number of example ABAP code snipts to help you use the functionality of this method.

This method is available within SAP systems depending on your version and release level, you can view further information by entering the class name IF_EX_BADI_MPL_IWB into the relevant SAP transactions such as SE24 or SE80, and then selecting the method you are interested in.


Method Type - Instance

This is an Instance Method so needs to be instantiated first before you can access any of the methods. I.e. you need to create a local variable of TYPE ref to the class.

The following technical details of method GET_VALID_PARTS_PER_LOC can also be found below:

  • Importing parameters
  • Exporting parameters
  • Changing parameters
  • Returning parameters
  • Exceptions
  • Coding Examples


Parameters of Method GET_VALID_PARTS_PER_LOC

.

NameTypeData TypeDescriptionDefault Value
CANCEL_PARTImportingTYPE
MATNR
old Material number
CHECK_CANCEL_PARTImportingTYPE
XFELD
Checkbox: Check cancel part
CHECK_ONLY_CURRENT_PARTImportingTYPE
XFELD
Checkbox: Check only the current part
CHECK_SETSImportingTYPE
XFELD
Checkbox: Check set relations
CLINTImportingTYPE
CLINT
Internal Class Number
CONF_AS_MAINTAINEDImportingTYPE
TT_CCM_TARGET_CONFIG_DETAIL
CCM: Configuration Data for MPL Explosion
CURRENT_PARTImportingTYPE
MATNR
Material number to be checked
EXPL_GUIDImportingTYPE
PVS_GUID
Internal identification for iPPE filter
INIT_ECMImportingTYPE
XFELD
Flag: init ECM
IR_BADI_CCM_FIDImportingTYPE REF TO
IF_EX_BADI_CCM_FID
IT_CLINTImportingTYPE
TT_CCM_CLINT
Table of iPPE product classes used in the MPL explosion
IV_CLINT_TABLE_CHANGEDImportingTYPE
XFELD
LEVELImportingTYPE
BALLEVEL
Application Log: Level of detail
LOG_HANDLEImportingTYPE
BALLOGHNDL
Application Log: Log handle
MOD_LISTImportingTYPE
TAB_MPL_MOD_LIST
Table of Mods per PPE Node
PFGUIDImportingTYPE
FOC_GUID
Internal Identification of Focus Record
PNGUIDImportingTYPE
PVS_PNGUID
Node to be investigated
PROBCLASSImportingTYPE
BALPROBCL
Application log: Message problem class
TECHSImportingTYPE
TECHS
Parameter variant/standard variant
ALL_PARTS_FOR_NODEExportingTYPE
TAB_MPL_MATERIALS_FOR_NODE
All materials for the node
PNODID_TABExportingTYPE
PPET_PNODID_LI_TAB
Attributes of the iPPE nodes
PNODTX_TABExportingTYPE
PPET_PNODTX_LI_TAB
Text attributes of iPPE nodes
VALID_PARTS_FOR_NODEExportingTYPE
TAB_MPL_MATERIALS_FOR_NODE
Valid materials for the node
CT_CONF_AS_MAINTAINEDChangingTYPE
TT_CCM_TARGET_CONFIG_DETAIL
CCM: Configuration Data for MPL Explosion
CUOBJChangingTYPE
CUOBJ
Configuration (internal object number)



Exceptions of Method GET_VALID_PARTS_PER_LOC

This method does not have any exceptions

Example ABAP coding


DATA: lo_class TYPE REF TO IF_EX_BADI_MPL_IWB.
DATA: lv_ALL_PARTS_FOR_NODE TYPE TAB_MPL_MATERIALS_FOR_NODE,
lv_CANCEL_PART TYPE MATNR,
lv_CHECK_CANCEL_PART TYPE XFELD,
lv_CHECK_ONLY_CURRENT_PART TYPE XFELD,
lv_CHECK_SETS TYPE XFELD,
lv_CLINT TYPE CLINT,
lv_CONF_AS_MAINTAINED TYPE TT_CCM_TARGET_CONFIG_DETAIL,
lv_CT_CONF_AS_MAINTAINED TYPE TT_CCM_TARGET_CONFIG_DETAIL,
lv_CUOBJ TYPE CUOBJ,
lv_CURRENT_PART TYPE MATNR,
lv_EXPL_GUID TYPE PVS_GUID,
lv_INIT_ECM TYPE XFELD,
lv_IR_BADI_CCM_FID TYPE IF_EX_BADI_CCM_FID,
lv_IT_CLINT TYPE TT_CCM_CLINT,
lv_IV_CLINT_TABLE_CHANGED TYPE XFELD,
lv_LEVEL TYPE BALLEVEL,
lv_LOG_HANDLE TYPE BALLOGHNDL,
lv_MOD_LIST TYPE TAB_MPL_MOD_LIST,
lv_PFGUID TYPE FOC_GUID,
lv_PNGUID TYPE PVS_PNGUID,
lv_PNODID_TAB TYPE PPET_PNODID_LI_TAB,
lv_PNODTX_TAB TYPE PPET_PNODTX_LI_TAB,
lv_PROBCLASS TYPE BALPROBCL,
lv_TECHS TYPE TECHS,
lv_VALID_PARTS_FOR_NODE TYPE TAB_MPL_MATERIALS_FOR_NODE,
lv_other TYPE c.

CALL METHOD lo_class=>GET_VALID_PARTS_PER_LOC(
EXPORTING
CANCEL_PART = lv_CANCEL_PART
CHECK_CANCEL_PART = lv_CHECK_CANCEL_PART
CHECK_ONLY_CURRENT_PART = lv_CHECK_ONLY_CURRENT_PART
CHECK_SETS = lv_CHECK_SETS
CLINT = lv_CLINT
CONF_AS_MAINTAINED = lv_CONF_AS_MAINTAINED
CURRENT_PART = lv_CURRENT_PART
EXPL_GUID = lv_EXPL_GUID
INIT_ECM = lv_INIT_ECM
IR_BADI_CCM_FID = lv_IR_BADI_CCM_FID
IT_CLINT = lv_IT_CLINT
IV_CLINT_TABLE_CHANGED = lv_IV_CLINT_TABLE_CHANGED
LEVEL = lv_LEVEL
LOG_HANDLE = lv_LOG_HANDLE
MOD_LIST = lv_MOD_LIST
PFGUID = lv_PFGUID
PNGUID = lv_PNGUID
PROBCLASS = lv_PROBCLASS
TECHS = lv_TECHS
IMPORTING
ALL_PARTS_FOR_NODE = lv_ALL_PARTS_FOR_NODE
PNODID_TAB = lv_PNODID_TAB
PNODTX_TAB = lv_PNODTX_TAB
VALID_PARTS_FOR_NODE = lv_VALID_PARTS_FOR_NODE
CHANGING
CT_CONF_AS_MAINTAINED = lv_CT_CONF_AS_MAINTAINED
CUOBJ = lv_CUOBJ ).

Links to Related Class(s)

IF_EX_BA...
Full list of available SAP object classes

Search for further information about these or an SAP related objects



Comments on this SAP object

What made you want to lookup this SAP object? Please tell us what you were looking for and anything you would like to be included on this page!