SAP RSD_CUBE_PART_GET Function Module for Gets an MPro / Hybr. InfoProvider with Iobj. and relation to
RSD_CUBE_PART_GET is a standard rsd cube part get SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used for Gets an MPro / Hybr. InfoProvider with Iobj. and relation to processing and below is the pattern details for this FM, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.
See here to view full function module documentation and code listing for rsd cube part get FM, simply by entering the name RSD_CUBE_PART_GET into the relevant SAP transaction such as SE37 or SE38.
Function Group: RSDG_CUBE_DB_READ
Program Name: SAPLRSDG_CUBE_DB_READ
Main Program: SAPLRSDG_CUBE_DB_READ
Appliation area: B
Release date: N/A
Mode(Normal, Remote etc): Normal Function Module
Update:

Function RSD_CUBE_PART_GET pattern details
In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.CALL FUNCTION 'RSD_CUBE_PART_GET'"Gets an MPro / Hybr. InfoProvider with Iobj. and relation to.
EXPORTING
I_INFOCUBE = "InfoCube
* I_OBJVERS = RS_C_OBJVERS-ACTIVE "Version
* I_INCL_APPEND = RS_C_TRUE "With Appends
* I_BYPASS_BUFFER = RS_C_FALSE "Bypass and Refresh Buffer (Indicator)
* I_WITH_ATR_NAV = RS_C_FALSE "Also read navigation attributes (flag)
IMPORTING
E_T_CUBE_PART = "involved InfoCubes
E_T_CUBE_PART_IOBJ = "InfoObjects in these InfoCubes
E_T_MULTI_IOBJ = "Relation: Iobj in MultiCube - Iobj in Involved Cube
CHANGING
* C_S_CUBE = "View of InfoCubes with texts
EXCEPTIONS
INFOCUBE_NOT_FOUND = 1 INFOCUBE_NOT_MULTI = 2 PART_CUBES_NOT_FOUND = 3 MULTI_IOBJ_NOT_FOUND = 4 ILLEGAL_INPUT = 5
IMPORTING Parameters details for RSD_CUBE_PART_GET
I_INFOCUBE - InfoCube
Data type: RSD_INFOCUBEOptional: No
Call by Reference: No ( called with pass by value option)
I_OBJVERS - Version
Data type: RS_OBJVERSDefault: RS_C_OBJVERS-ACTIVE
Optional: Yes
Call by Reference: No ( called with pass by value option)
I_INCL_APPEND - With Appends
Data type: RS_BOOLDefault: RS_C_TRUE
Optional: Yes
Call by Reference: No ( called with pass by value option)
I_BYPASS_BUFFER - Bypass and Refresh Buffer (Indicator)
Data type: RS_BOOLDefault: RS_C_FALSE
Optional: Yes
Call by Reference: No ( called with pass by value option)
I_WITH_ATR_NAV - Also read navigation attributes (flag)
Data type: RS_BOOLDefault: RS_C_FALSE
Optional: Yes
Call by Reference: No ( called with pass by value option)
EXPORTING Parameters details for RSD_CUBE_PART_GET
E_T_CUBE_PART - involved InfoCubes
Data type: RSD_T_CUBE_PARTOptional: No
Call by Reference: Yes
E_T_CUBE_PART_IOBJ - InfoObjects in these InfoCubes
Data type: RSD_T_CUBE_IOBJOptional: No
Call by Reference: Yes
E_T_MULTI_IOBJ - Relation: Iobj in MultiCube - Iobj in Involved Cube
Data type: RSD_T_MULTI_IOBJOptional: No
Call by Reference: Yes
CHANGING Parameters details for RSD_CUBE_PART_GET
C_S_CUBE - View of InfoCubes with texts
Data type: RSDCUBEVOptional: Yes
Call by Reference: Yes
EXCEPTIONS details
INFOCUBE_NOT_FOUND - InfoCube does not exist
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
INFOCUBE_NOT_MULTI - InfoCube is not MultiCube
Data type:Optional: No
Call by Reference: Yes
PART_CUBES_NOT_FOUND - Involved InfoCubes are not found
Data type:Optional: No
Call by Reference: Yes
MULTI_IOBJ_NOT_FOUND - Relation: InfoObj in MC <-> InfoObj not found in the PC
Data type:Optional: No
Call by Reference: Yes
ILLEGAL_INPUT - Invalid Entry
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
Copy and paste ABAP code example for RSD_CUBE_PART_GET Function Module
The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.| DATA: | ||||
| lv_c_s_cube | TYPE RSDCUBEV, " | |||
| lv_i_infocube | TYPE RSD_INFOCUBE, " | |||
| lv_e_t_cube_part | TYPE RSD_T_CUBE_PART, " | |||
| lv_infocube_not_found | TYPE RSD_T_CUBE_PART, " | |||
| lv_i_objvers | TYPE RS_OBJVERS, " RS_C_OBJVERS-ACTIVE | |||
| lv_e_t_cube_part_iobj | TYPE RSD_T_CUBE_IOBJ, " | |||
| lv_infocube_not_multi | TYPE RSD_T_CUBE_IOBJ, " | |||
| lv_i_incl_append | TYPE RS_BOOL, " RS_C_TRUE | |||
| lv_e_t_multi_iobj | TYPE RSD_T_MULTI_IOBJ, " | |||
| lv_part_cubes_not_found | TYPE RSD_T_MULTI_IOBJ, " | |||
| lv_i_bypass_buffer | TYPE RS_BOOL, " RS_C_FALSE | |||
| lv_multi_iobj_not_found | TYPE RS_BOOL, " | |||
| lv_illegal_input | TYPE RS_BOOL, " | |||
| lv_i_with_atr_nav | TYPE RS_BOOL. " RS_C_FALSE |
|   CALL FUNCTION 'RSD_CUBE_PART_GET' "Gets an MPro / Hybr. InfoProvider with Iobj. and relation to |
| EXPORTING | ||
| I_INFOCUBE | = lv_i_infocube | |
| I_OBJVERS | = lv_i_objvers | |
| I_INCL_APPEND | = lv_i_incl_append | |
| I_BYPASS_BUFFER | = lv_i_bypass_buffer | |
| I_WITH_ATR_NAV | = lv_i_with_atr_nav | |
| IMPORTING | ||
| E_T_CUBE_PART | = lv_e_t_cube_part | |
| E_T_CUBE_PART_IOBJ | = lv_e_t_cube_part_iobj | |
| E_T_MULTI_IOBJ | = lv_e_t_multi_iobj | |
| CHANGING | ||
| C_S_CUBE | = lv_c_s_cube | |
| EXCEPTIONS | ||
| INFOCUBE_NOT_FOUND = 1 | ||
| INFOCUBE_NOT_MULTI = 2 | ||
| PART_CUBES_NOT_FOUND = 3 | ||
| MULTI_IOBJ_NOT_FOUND = 4 | ||
| ILLEGAL_INPUT = 5 | ||
| . " RSD_CUBE_PART_GET | ||
ABAP code using 7.40 inline data declarations to call FM RSD_CUBE_PART_GET
The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.| DATA(ld_i_objvers) | = RS_C_OBJVERS-ACTIVE. | |||
| DATA(ld_i_incl_append) | = RS_C_TRUE. | |||
| DATA(ld_i_bypass_buffer) | = RS_C_FALSE. | |||
| DATA(ld_i_with_atr_nav) | = RS_C_FALSE. | |||
Search for further information about these or an SAP related objects