SAP ISU_MREADING_INTERPOL_CHECK Function Module for INTERNAL: Check Whether Interpolation Can Take Place
ISU_MREADING_INTERPOL_CHECK is a standard isu mreading interpol check SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used for INTERNAL: Check Whether Interpolation Can Take Place processing and below is the pattern details for this FM, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.
See here to view full function module documentation and code listing for isu mreading interpol check FM, simply by entering the name ISU_MREADING_INTERPOL_CHECK into the relevant SAP transaction such as SE37 or SE38.
Function Group: ELKA
Program Name: SAPLELKA
Main Program: SAPLELKA
Appliation area: E
Release date: N/A
Mode(Normal, Remote etc): Normal Function Module
Update:

Function ISU_MREADING_INTERPOL_CHECK pattern details
In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.CALL FUNCTION 'ISU_MREADING_INTERPOL_CHECK'"INTERNAL: Check Whether Interpolation Can Take Place.
EXPORTING
X_EQUNR = "
* X_TARIFART = "
* X_TARIFTYP = "
X_ADATSOLL = "Scheduled Meter Reading Date
* X_ZUORDDAT = "Meter reading allocation date
* X_ABLESARTST = "
X_ABLESGR = "Meter Reading Reason
* X_EBENE = "
* X_NO_DIALOG = "
* X_GERNR = "Device Number
X_ZWNUMMER = "Register Number
X_ZWTYP = "Register Category
X_ABLEINH = "Meter Reading Unit
X_ANLAGE = "
X_BUKRS = "Company Code
X_SPARTE = "Division
* X_SPARTYP = "
CHANGING
XY_OBJ = "
TABLES
* TX_EABL = "
* TX_EABLG = "
* TY_EABLQDCONV = "
EXCEPTIONS
NOT_FOUND = 1 FOREIGN_LOCK = 2 INTERNAL_ERROR = 3 INPUT_ERROR = 4 EXISTING = 5 NUMBER_ERROR = 6 SYSTEM_ERROR = 7 GENERAL_FAULT = 8
Customer Function user exits
Below is a list of CUSTOMER FUNCTION exit user exits that are available within this program and maybe relevant for this FM.EXIT_SAPLELKA_001 IS-U: Customer-Specific Suppression of Automatic Interpolation
IMPORTING Parameters details for ISU_MREADING_INTERPOL_CHECK
X_EQUNR -
Data type: EABLD-EQUNROptional: No
Call by Reference: No ( called with pass by value option)
X_TARIFART -
Data type: TARIFARTOptional: Yes
Call by Reference: No ( called with pass by value option)
X_TARIFTYP -
Data type: TARIFTYPOptional: Yes
Call by Reference: No ( called with pass by value option)
X_ADATSOLL - Scheduled Meter Reading Date
Data type: EABLD-ADATSOLLOptional: No
Call by Reference: No ( called with pass by value option)
X_ZUORDDAT - Meter reading allocation date
Data type: EABLD-ZUORDDATOptional: Yes
Call by Reference: No ( called with pass by value option)
X_ABLESARTST -
Data type: EABLD-ABLESARTSTOptional: Yes
Call by Reference: No ( called with pass by value option)
X_ABLESGR - Meter Reading Reason
Data type: EABLG-ABLESGROptional: No
Call by Reference: No ( called with pass by value option)
X_EBENE -
Data type: REL01-VB_EBENEOptional: Yes
Call by Reference: No ( called with pass by value option)
X_NO_DIALOG -
Data type: REGEN-NO_DIALOGOptional: Yes
Call by Reference: No ( called with pass by value option)
X_GERNR - Device Number
Data type: EABLD-GERNROptional: Yes
Call by Reference: No ( called with pass by value option)
X_ZWNUMMER - Register Number
Data type: EABLD-ZWNUMMEROptional: No
Call by Reference: No ( called with pass by value option)
X_ZWTYP - Register Category
Data type: ETDZ-ZWTYPOptional: No
Call by Reference: No ( called with pass by value option)
X_ABLEINH - Meter Reading Unit
Data type: EABLD-ABLEINHOptional: No
Call by Reference: No ( called with pass by value option)
X_ANLAGE -
Data type: EABLD-ANLAGEOptional: No
Call by Reference: No ( called with pass by value option)
X_BUKRS - Company Code
Data type: EABLD-BUKRSOptional: No
Call by Reference: No ( called with pass by value option)
X_SPARTE - Division
Data type: EABLD-SPARTEOptional: No
Call by Reference: No ( called with pass by value option)
X_SPARTYP -
Data type: SPARTYPOptional: Yes
Call by Reference: No ( called with pass by value option)
CHANGING Parameters details for ISU_MREADING_INTERPOL_CHECK
XY_OBJ -
Data type: ISU17_METERREADOptional: No
Call by Reference: Yes
TABLES Parameters details for ISU_MREADING_INTERPOL_CHECK
TX_EABL -
Data type: EABLOptional: Yes
Call by Reference: No ( called with pass by value option)
TX_EABLG -
Data type: EABLGOptional: Yes
Call by Reference: No ( called with pass by value option)
TY_EABLQDCONV -
Data type: EABLQDCONVOptional: Yes
Call by Reference: Yes
EXCEPTIONS details
NOT_FOUND -
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
FOREIGN_LOCK -
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
INTERNAL_ERROR - Internal Error
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
INPUT_ERROR - Error During Entry Check
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
EXISTING - Object Already Exists
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
NUMBER_ERROR - Error in number assignment
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
SYSTEM_ERROR - System error
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
GENERAL_FAULT - General Error
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
Copy and paste ABAP code example for ISU_MREADING_INTERPOL_CHECK Function Module
The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.| DATA: | ||||
| lv_xy_obj | TYPE ISU17_METERREAD, " | |||
| lt_tx_eabl | TYPE STANDARD TABLE OF EABL, " | |||
| lv_x_equnr | TYPE EABLD-EQUNR, " | |||
| lv_not_found | TYPE EABLD, " | |||
| lv_x_tarifart | TYPE TARIFART, " | |||
| lv_x_tariftyp | TYPE TARIFTYP, " | |||
| lv_x_adatsoll | TYPE EABLD-ADATSOLL, " | |||
| lv_x_zuorddat | TYPE EABLD-ZUORDDAT, " | |||
| lv_x_ablesartst | TYPE EABLD-ABLESARTST, " | |||
| lv_x_ablesgr | TYPE EABLG-ABLESGR, " | |||
| lv_x_ebene | TYPE REL01-VB_EBENE, " | |||
| lv_x_no_dialog | TYPE REGEN-NO_DIALOG, " | |||
| lv_x_gernr | TYPE EABLD-GERNR, " | |||
| lt_tx_eablg | TYPE STANDARD TABLE OF EABLG, " | |||
| lv_foreign_lock | TYPE EABLG, " | |||
| lv_x_zwnummer | TYPE EABLD-ZWNUMMER, " | |||
| lt_ty_eablqdconv | TYPE STANDARD TABLE OF EABLQDCONV, " | |||
| lv_internal_error | TYPE EABLQDCONV, " | |||
| lv_x_zwtyp | TYPE ETDZ-ZWTYP, " | |||
| lv_input_error | TYPE ETDZ, " | |||
| lv_existing | TYPE ETDZ, " | |||
| lv_x_ableinh | TYPE EABLD-ABLEINH, " | |||
| lv_x_anlage | TYPE EABLD-ANLAGE, " | |||
| lv_number_error | TYPE EABLD, " | |||
| lv_x_bukrs | TYPE EABLD-BUKRS, " | |||
| lv_system_error | TYPE EABLD, " | |||
| lv_x_sparte | TYPE EABLD-SPARTE, " | |||
| lv_general_fault | TYPE EABLD, " | |||
| lv_x_spartyp | TYPE SPARTYP. " |
|   CALL FUNCTION 'ISU_MREADING_INTERPOL_CHECK' "INTERNAL: Check Whether Interpolation Can Take Place |
| EXPORTING | ||
| X_EQUNR | = lv_x_equnr | |
| X_TARIFART | = lv_x_tarifart | |
| X_TARIFTYP | = lv_x_tariftyp | |
| X_ADATSOLL | = lv_x_adatsoll | |
| X_ZUORDDAT | = lv_x_zuorddat | |
| X_ABLESARTST | = lv_x_ablesartst | |
| X_ABLESGR | = lv_x_ablesgr | |
| X_EBENE | = lv_x_ebene | |
| X_NO_DIALOG | = lv_x_no_dialog | |
| X_GERNR | = lv_x_gernr | |
| X_ZWNUMMER | = lv_x_zwnummer | |
| X_ZWTYP | = lv_x_zwtyp | |
| X_ABLEINH | = lv_x_ableinh | |
| X_ANLAGE | = lv_x_anlage | |
| X_BUKRS | = lv_x_bukrs | |
| X_SPARTE | = lv_x_sparte | |
| X_SPARTYP | = lv_x_spartyp | |
| CHANGING | ||
| XY_OBJ | = lv_xy_obj | |
| TABLES | ||
| TX_EABL | = lt_tx_eabl | |
| TX_EABLG | = lt_tx_eablg | |
| TY_EABLQDCONV | = lt_ty_eablqdconv | |
| EXCEPTIONS | ||
| NOT_FOUND = 1 | ||
| FOREIGN_LOCK = 2 | ||
| INTERNAL_ERROR = 3 | ||
| INPUT_ERROR = 4 | ||
| EXISTING = 5 | ||
| NUMBER_ERROR = 6 | ||
| SYSTEM_ERROR = 7 | ||
| GENERAL_FAULT = 8 | ||
| . " ISU_MREADING_INTERPOL_CHECK | ||
ABAP code using 7.40 inline data declarations to call FM ISU_MREADING_INTERPOL_CHECK
The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.| "SELECT single EQUNR FROM EABLD INTO @DATA(ld_x_equnr). | ||||
| "SELECT single ADATSOLL FROM EABLD INTO @DATA(ld_x_adatsoll). | ||||
| "SELECT single ZUORDDAT FROM EABLD INTO @DATA(ld_x_zuorddat). | ||||
| "SELECT single ABLESARTST FROM EABLD INTO @DATA(ld_x_ablesartst). | ||||
| "SELECT single ABLESGR FROM EABLG INTO @DATA(ld_x_ablesgr). | ||||
| "SELECT single VB_EBENE FROM REL01 INTO @DATA(ld_x_ebene). | ||||
| "SELECT single NO_DIALOG FROM REGEN INTO @DATA(ld_x_no_dialog). | ||||
| "SELECT single GERNR FROM EABLD INTO @DATA(ld_x_gernr). | ||||
| "SELECT single ZWNUMMER FROM EABLD INTO @DATA(ld_x_zwnummer). | ||||
| "SELECT single ZWTYP FROM ETDZ INTO @DATA(ld_x_zwtyp). | ||||
| "SELECT single ABLEINH FROM EABLD INTO @DATA(ld_x_ableinh). | ||||
| "SELECT single ANLAGE FROM EABLD INTO @DATA(ld_x_anlage). | ||||
| "SELECT single BUKRS FROM EABLD INTO @DATA(ld_x_bukrs). | ||||
| "SELECT single SPARTE FROM EABLD INTO @DATA(ld_x_sparte). | ||||
Search for further information about these or an SAP related objects