SAP ISU_DB_INSTALL_STRUC_SELECT Function Module for INTERNAL: Read Installation Structure of Installation Return All to Table
ISU_DB_INSTALL_STRUC_SELECT is a standard isu db install struc select SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used for INTERNAL: Read Installation Structure of Installation Return All to Table processing and below is the pattern details for this FM, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.
See here to view full function module documentation and code listing for isu db install struc select FM, simply by entering the name ISU_DB_INSTALL_STRUC_SELECT into the relevant SAP transaction such as SE37 or SE38.
Function Group: E70U
Program Name: SAPLE70U
Main Program: SAPLE70U
Appliation area: E
Release date: N/A
Mode(Normal, Remote etc): Normal Function Module
Update:

Function ISU_DB_INSTALL_STRUC_SELECT pattern details
In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.CALL FUNCTION 'ISU_DB_INSTALL_STRUC_SELECT'"INTERNAL: Read Installation Structure of Installation Return All to Table.
EXPORTING
X_ANLAGE = "Installation
TABLES
* T_IEASTL = "Billing Data: Installation Structure at Device Level
* T_IEASTS_OLD = "Billing Data: Installation Structure at Register Level
* T_IEASTI_OLD = "Register relationships
* T_IEASTIH_OLD = "
* T_IEZUG_OLD = "Device allocations at device level
* T_IEZUZ_OLD = "Device allocations at register level
* T_IEADZ_OLD = "
* T_IETDZ_OLD = "Technical data for installed register
* T_IEADZ_QD = "
* T_IEADZ_QD_OLD = "
* T_IEASTS = "Billing Data: Installation Structure at Register Level
* T_IEASTI = "Register relationships
* T_IEASTIH = "
* T_IEZUG = "Device allocations at device level
* T_IEZUZ = "Device allocations at register level
* T_IEADZ = "
* T_IETDZ = "Technical data for installed register
* T_IEASTL_OLD = "Billing Data: Installation Structure at Device Level
EXCEPTIONS
NOT_FOUND = 1 SYSTEM_ERROR = 2
IMPORTING Parameters details for ISU_DB_INSTALL_STRUC_SELECT
X_ANLAGE - Installation
Data type: EASTL-ANLAGEOptional: No
Call by Reference: No ( called with pass by value option)
TABLES Parameters details for ISU_DB_INSTALL_STRUC_SELECT
T_IEASTL - Billing Data: Installation Structure at Device Level
Data type: EASTLOptional: Yes
Call by Reference: Yes
T_IEASTS_OLD - Billing Data: Installation Structure at Register Level
Data type: EASTSOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEASTI_OLD - Register relationships
Data type: EASTIOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEASTIH_OLD -
Data type: EASTIHOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEZUG_OLD - Device allocations at device level
Data type: EZUGOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEZUZ_OLD - Device allocations at register level
Data type: EZUZOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEADZ_OLD -
Data type: EADZOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IETDZ_OLD - Technical data for installed register
Data type: ETDZOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEADZ_QD -
Data type: EADZ_QDOptional: Yes
Call by Reference: Yes
T_IEADZ_QD_OLD -
Data type: EADZ_QDOptional: Yes
Call by Reference: Yes
T_IEASTS - Billing Data: Installation Structure at Register Level
Data type: EASTSOptional: Yes
Call by Reference: Yes
T_IEASTI - Register relationships
Data type: EASTIOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEASTIH -
Data type: EASTIHOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEZUG - Device allocations at device level
Data type: EZUGOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEZUZ - Device allocations at register level
Data type: EZUZOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEADZ -
Data type: EADZOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IETDZ - Technical data for installed register
Data type: ETDZOptional: Yes
Call by Reference: No ( called with pass by value option)
T_IEASTL_OLD - Billing Data: Installation Structure at Device Level
Data type: EASTLOptional: Yes
Call by Reference: No ( called with pass by value option)
EXCEPTIONS details
NOT_FOUND - Object Not Found
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
SYSTEM_ERROR - Other Error
Data type:Optional: No
Call by Reference: No ( called with pass by value option)
Copy and paste ABAP code example for ISU_DB_INSTALL_STRUC_SELECT Function Module
The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.| DATA: | ||||
| lt_t_ieastl | TYPE STANDARD TABLE OF EASTL, " | |||
| lv_x_anlage | TYPE EASTL-ANLAGE, " | |||
| lv_not_found | TYPE EASTL, " | |||
| lt_t_ieasts_old | TYPE STANDARD TABLE OF EASTS, " | |||
| lt_t_ieasti_old | TYPE STANDARD TABLE OF EASTI, " | |||
| lt_t_ieastih_old | TYPE STANDARD TABLE OF EASTIH, " | |||
| lt_t_iezug_old | TYPE STANDARD TABLE OF EZUG, " | |||
| lt_t_iezuz_old | TYPE STANDARD TABLE OF EZUZ, " | |||
| lt_t_ieadz_old | TYPE STANDARD TABLE OF EADZ, " | |||
| lt_t_ietdz_old | TYPE STANDARD TABLE OF ETDZ, " | |||
| lt_t_ieadz_qd | TYPE STANDARD TABLE OF EADZ_QD, " | |||
| lt_t_ieadz_qd_old | TYPE STANDARD TABLE OF EADZ_QD, " | |||
| lt_t_ieasts | TYPE STANDARD TABLE OF EASTS, " | |||
| lv_system_error | TYPE EASTS, " | |||
| lt_t_ieasti | TYPE STANDARD TABLE OF EASTI, " | |||
| lt_t_ieastih | TYPE STANDARD TABLE OF EASTIH, " | |||
| lt_t_iezug | TYPE STANDARD TABLE OF EZUG, " | |||
| lt_t_iezuz | TYPE STANDARD TABLE OF EZUZ, " | |||
| lt_t_ieadz | TYPE STANDARD TABLE OF EADZ, " | |||
| lt_t_ietdz | TYPE STANDARD TABLE OF ETDZ, " | |||
| lt_t_ieastl_old | TYPE STANDARD TABLE OF EASTL. " |
|   CALL FUNCTION 'ISU_DB_INSTALL_STRUC_SELECT' "INTERNAL: Read Installation Structure of Installation Return All to Table |
| EXPORTING | ||
| X_ANLAGE | = lv_x_anlage | |
| TABLES | ||
| T_IEASTL | = lt_t_ieastl | |
| T_IEASTS_OLD | = lt_t_ieasts_old | |
| T_IEASTI_OLD | = lt_t_ieasti_old | |
| T_IEASTIH_OLD | = lt_t_ieastih_old | |
| T_IEZUG_OLD | = lt_t_iezug_old | |
| T_IEZUZ_OLD | = lt_t_iezuz_old | |
| T_IEADZ_OLD | = lt_t_ieadz_old | |
| T_IETDZ_OLD | = lt_t_ietdz_old | |
| T_IEADZ_QD | = lt_t_ieadz_qd | |
| T_IEADZ_QD_OLD | = lt_t_ieadz_qd_old | |
| T_IEASTS | = lt_t_ieasts | |
| T_IEASTI | = lt_t_ieasti | |
| T_IEASTIH | = lt_t_ieastih | |
| T_IEZUG | = lt_t_iezug | |
| T_IEZUZ | = lt_t_iezuz | |
| T_IEADZ | = lt_t_ieadz | |
| T_IETDZ | = lt_t_ietdz | |
| T_IEASTL_OLD | = lt_t_ieastl_old | |
| EXCEPTIONS | ||
| NOT_FOUND = 1 | ||
| SYSTEM_ERROR = 2 | ||
| . " ISU_DB_INSTALL_STRUC_SELECT | ||
ABAP code using 7.40 inline data declarations to call FM ISU_DB_INSTALL_STRUC_SELECT
The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.| "SELECT single ANLAGE FROM EASTL INTO @DATA(ld_x_anlage). | ||||
Search for further information about these or an SAP related objects