SAP DEQUEUE_ERACK_SIM Function Module for Release lock on object ERACK_SIM









DEQUEUE_ERACK_SIM is a standard dequeue erack sim SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used for Release lock on object ERACK_SIM processing and below is the pattern details for this FM, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.


See here to view full function module documentation and code listing for dequeue erack sim FM, simply by entering the name DEQUEUE_ERACK_SIM into the relevant SAP transaction such as SE37 or SE38.

Function Group: /1BCDWBEN/OEN0008
Program Name: /1BCDWBEN/SAPLOEN0008
Main Program:
Appliation area:
Release date: N/A
Mode(Normal, Remote etc): Normal Function Module
Update:



Function DEQUEUE_ERACK_SIM pattern details

In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.
CALL FUNCTION 'DEQUEUE_ERACK_SIM'"Release lock on object ERACK_SIM
EXPORTING
* MODE_OIJTHPUTFC_SIM = 'E' "Lock mode for table OIJTHPUTFC_SIM
* CUFCTYPE = "09th enqueue argument
* THPFCIND = "10th enqueue argument
* SCENARIO_ID = "11th enqueue argument
* SIM_VERSION = "12th enqueue argument
* X_LOCID = ' ' "Fill argument 02 with initial value?
* X_SOCNR = ' ' "Fill argument 03 with initial value?
* X_MATNR = ' ' "Fill argument 04 with initial value?
* X_CHARG = ' ' "Fill argument 05 with initial value?
* X_DATUM = ' ' "Fill argument 06 with initial value?
* X_VKTRA = ' ' "Fill argument 07 with initial value?
* MANDT = SY-MANDT "01th enqueue argument
* X_FCTYPE = ' ' "Fill argument 08 with initial value?
* X_CUFCTYPE = ' ' "Fill argument 09 with initial value?
* X_THPFCIND = ' ' "Fill argument 10 with initial value?
* X_SCENARIO_ID = ' ' "Fill argument 11 with initial value?
* X_SIM_VERSION = ' ' "Fill argument 12 with initial value?
* _SCOPE = '3' "
* _SYNCHRON = ' ' "Synchonous unlock
* _COLLECT = ' ' "Initially only collect lock
* LOCID = "02th enqueue argument
* SOCNR = "03th enqueue argument
* MATNR = "04th enqueue argument
* CHARG = "05th enqueue argument
* DATUM = "06th enqueue argument
* VKTRA = "07th enqueue argument
* FCTYPE = "08th enqueue argument
.



IMPORTING Parameters details for DEQUEUE_ERACK_SIM

MODE_OIJTHPUTFC_SIM - Lock mode for table OIJTHPUTFC_SIM

Data type: ENQMODE
Default: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)

CUFCTYPE - 09th enqueue argument

Data type: OIJTHPUTFC_SIM-CUFCTYPE
Optional: Yes
Call by Reference: No ( called with pass by value option)

THPFCIND - 10th enqueue argument

Data type: OIJTHPUTFC_SIM-THPFCIND
Optional: Yes
Call by Reference: No ( called with pass by value option)

SCENARIO_ID - 11th enqueue argument

Data type: OIJTHPUTFC_SIM-SCENARIO_ID
Optional: Yes
Call by Reference: No ( called with pass by value option)

SIM_VERSION - 12th enqueue argument

Data type: OIJTHPUTFC_SIM-SIM_VERSION
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_LOCID - Fill argument 02 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_SOCNR - Fill argument 03 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_MATNR - Fill argument 04 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_CHARG - Fill argument 05 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_DATUM - Fill argument 06 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_VKTRA - Fill argument 07 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

MANDT - 01th enqueue argument

Data type: OIJTHPUTFC_SIM-MANDT
Default: SY-MANDT
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_FCTYPE - Fill argument 08 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_CUFCTYPE - Fill argument 09 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_THPFCIND - Fill argument 10 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_SCENARIO_ID - Fill argument 11 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_SIM_VERSION - Fill argument 12 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

_SCOPE -

Data type:
Default: '3'
Optional: Yes
Call by Reference: No ( called with pass by value option)

_SYNCHRON - Synchonous unlock

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

_COLLECT - Initially only collect lock

Data type: DDENQCOLL
Default: ' '
Optional: Yes
Call by Reference: No ( called with pass by value option)

LOCID - 02th enqueue argument

Data type: OIJTHPUTFC_SIM-LOCID
Optional: Yes
Call by Reference: No ( called with pass by value option)

SOCNR - 03th enqueue argument

Data type: OIJTHPUTFC_SIM-SOCNR
Optional: Yes
Call by Reference: No ( called with pass by value option)

MATNR - 04th enqueue argument

Data type: OIJTHPUTFC_SIM-MATNR
Optional: Yes
Call by Reference: No ( called with pass by value option)

CHARG - 05th enqueue argument

Data type: OIJTHPUTFC_SIM-CHARG
Optional: Yes
Call by Reference: No ( called with pass by value option)

DATUM - 06th enqueue argument

Data type: OIJTHPUTFC_SIM-DATUM
Optional: Yes
Call by Reference: No ( called with pass by value option)

VKTRA - 07th enqueue argument

Data type: OIJTHPUTFC_SIM-VKTRA
Optional: Yes
Call by Reference: No ( called with pass by value option)

FCTYPE - 08th enqueue argument

Data type: OIJTHPUTFC_SIM-FCTYPE
Optional: Yes
Call by Reference: No ( called with pass by value option)

Copy and paste ABAP code example for DEQUEUE_ERACK_SIM Function Module

The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.

DATA:
lv_mode_oijthputfc_sim  TYPE ENQMODE, "   'E'
lv_cufctype  TYPE OIJTHPUTFC_SIM-CUFCTYPE, "   
lv_thpfcind  TYPE OIJTHPUTFC_SIM-THPFCIND, "   
lv_scenario_id  TYPE OIJTHPUTFC_SIM-SCENARIO_ID, "   
lv_sim_version  TYPE OIJTHPUTFC_SIM-SIM_VERSION, "   
lv_x_locid  TYPE OIJTHPUTFC_SIM, "   SPACE
lv_x_socnr  TYPE OIJTHPUTFC_SIM, "   SPACE
lv_x_matnr  TYPE OIJTHPUTFC_SIM, "   SPACE
lv_x_charg  TYPE OIJTHPUTFC_SIM, "   SPACE
lv_x_datum  TYPE OIJTHPUTFC_SIM, "   SPACE
lv_x_vktra  TYPE OIJTHPUTFC_SIM, "   SPACE
lv_mandt  TYPE OIJTHPUTFC_SIM-MANDT, "   SY-MANDT
lv_x_fctype  TYPE OIJTHPUTFC_SIM, "   SPACE
lv_x_cufctype  TYPE OIJTHPUTFC_SIM, "   SPACE
lv_x_thpfcind  TYPE OIJTHPUTFC_SIM, "   SPACE
lv_x_scenario_id  TYPE OIJTHPUTFC_SIM, "   SPACE
lv_x_sim_version  TYPE OIJTHPUTFC_SIM, "   SPACE
lv__scope  TYPE OIJTHPUTFC_SIM, "   '3'
lv__synchron  TYPE OIJTHPUTFC_SIM, "   SPACE
lv__collect  TYPE DDENQCOLL, "   ' '
lv_locid  TYPE OIJTHPUTFC_SIM-LOCID, "   
lv_socnr  TYPE OIJTHPUTFC_SIM-SOCNR, "   
lv_matnr  TYPE OIJTHPUTFC_SIM-MATNR, "   
lv_charg  TYPE OIJTHPUTFC_SIM-CHARG, "   
lv_datum  TYPE OIJTHPUTFC_SIM-DATUM, "   
lv_vktra  TYPE OIJTHPUTFC_SIM-VKTRA, "   
lv_fctype  TYPE OIJTHPUTFC_SIM-FCTYPE. "   

  CALL FUNCTION 'DEQUEUE_ERACK_SIM'  "Release lock on object ERACK_SIM
    EXPORTING
         MODE_OIJTHPUTFC_SIM = lv_mode_oijthputfc_sim
         CUFCTYPE = lv_cufctype
         THPFCIND = lv_thpfcind
         SCENARIO_ID = lv_scenario_id
         SIM_VERSION = lv_sim_version
         X_LOCID = lv_x_locid
         X_SOCNR = lv_x_socnr
         X_MATNR = lv_x_matnr
         X_CHARG = lv_x_charg
         X_DATUM = lv_x_datum
         X_VKTRA = lv_x_vktra
         MANDT = lv_mandt
         X_FCTYPE = lv_x_fctype
         X_CUFCTYPE = lv_x_cufctype
         X_THPFCIND = lv_x_thpfcind
         X_SCENARIO_ID = lv_x_scenario_id
         X_SIM_VERSION = lv_x_sim_version
         _SCOPE = lv__scope
         _SYNCHRON = lv__synchron
         _COLLECT = lv__collect
         LOCID = lv_locid
         SOCNR = lv_socnr
         MATNR = lv_matnr
         CHARG = lv_charg
         DATUM = lv_datum
         VKTRA = lv_vktra
         FCTYPE = lv_fctype
. " DEQUEUE_ERACK_SIM




ABAP code using 7.40 inline data declarations to call FM DEQUEUE_ERACK_SIM

The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.

DATA(ld_mode_oijthputfc_sim) = 'E'.
 
"SELECT single CUFCTYPE FROM OIJTHPUTFC_SIM INTO @DATA(ld_cufctype).
 
"SELECT single THPFCIND FROM OIJTHPUTFC_SIM INTO @DATA(ld_thpfcind).
 
"SELECT single SCENARIO_ID FROM OIJTHPUTFC_SIM INTO @DATA(ld_scenario_id).
 
"SELECT single SIM_VERSION FROM OIJTHPUTFC_SIM INTO @DATA(ld_sim_version).
 
DATA(ld_x_locid) = ' '.
 
DATA(ld_x_socnr) = ' '.
 
DATA(ld_x_matnr) = ' '.
 
DATA(ld_x_charg) = ' '.
 
DATA(ld_x_datum) = ' '.
 
DATA(ld_x_vktra) = ' '.
 
"SELECT single MANDT FROM OIJTHPUTFC_SIM INTO @DATA(ld_mandt).
DATA(ld_mandt) = SY-MANDT.
 
DATA(ld_x_fctype) = ' '.
 
DATA(ld_x_cufctype) = ' '.
 
DATA(ld_x_thpfcind) = ' '.
 
DATA(ld_x_scenario_id) = ' '.
 
DATA(ld_x_sim_version) = ' '.
 
DATA(ld__scope) = '3'.
 
DATA(ld__synchron) = ' '.
 
DATA(ld__collect) = ' '.
 
"SELECT single LOCID FROM OIJTHPUTFC_SIM INTO @DATA(ld_locid).
 
"SELECT single SOCNR FROM OIJTHPUTFC_SIM INTO @DATA(ld_socnr).
 
"SELECT single MATNR FROM OIJTHPUTFC_SIM INTO @DATA(ld_matnr).
 
"SELECT single CHARG FROM OIJTHPUTFC_SIM INTO @DATA(ld_charg).
 
"SELECT single DATUM FROM OIJTHPUTFC_SIM INTO @DATA(ld_datum).
 
"SELECT single VKTRA FROM OIJTHPUTFC_SIM INTO @DATA(ld_vktra).
 
"SELECT single FCTYPE FROM OIJTHPUTFC_SIM INTO @DATA(ld_fctype).
 


Search for further information about these or an SAP related objects



Comments on this SAP object

What made you want to lookup this SAP object? Please tell us what you were looking for and anything you would like to be included on this page!