SAP DEQUEUE_EPT514D Function Module for Release lock on object EPT514D
DEQUEUE_EPT514D is a standard dequeue ept514d SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used for Release lock on object EPT514D processing and below is the pattern details for this FM, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.
See here to view full function module documentation and code listing for dequeue ept514d FM, simply by entering the name DEQUEUE_EPT514D into the relevant SAP transaction such as SE37 or SE38.
Function Group: /1BCDWBEN/PEN0000
Program Name: /1BCDWBEN/SAPLPEN0000
Main Program:
Appliation area:
Release date: N/A
Mode(Normal, Remote etc): Normal Function Module
Update:

Function DEQUEUE_EPT514D pattern details
In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.CALL FUNCTION 'DEQUEUE_EPT514D'"Release lock on object EPT514D.
EXPORTING
* MODE_T514D = 'E' "Lock mode for table T514D
* MODE_T512Q = 'E' "Lock mode for table T512Q
* MODE_T512P = 'E' "Lock mode for table T512P
* MANDT = SY-MANDT "01th enqueue argument
* MOLGA = "02th enqueue argument
* FORML = "03th enqueue argument
* LGART = "04th enqueue argument
* SPRSL = "05th enqueue argument
* LGART2 = "06th enqueue argument
* SPRSL2 = "07th enqueue argument
* LTYPE = "08th enqueue argument
* MODE_T512R = 'E' "Lock mode for table T512R
* COLNO = "09th enqueue argument
* FOFFS = "10th enqueue argument
* LGART3 = "11th enqueue argument
* TABNA = "12th enqueue argument
* LFDNR = "13th enqueue argument
* WINDO = "14th enqueue argument
* SPRSL3 = "15th enqueue argument
* WINDO2 = "16th enqueue argument
* GRPPE = "17th enqueue argument
* KENNZ = "18th enqueue argument
* MODE_T512S = 'E' "Lock mode for table T512S
* LFDNR2 = "19th enqueue argument
* REGEL = "20th enqueue argument
* LFDNR3 = "21th enqueue argument
* PTYPE = "22th enqueue argument
* LINNO = "23th enqueue argument
* FOFFS2 = "24th enqueue argument
* SPRSL4 = "25th enqueue argument
* LINNO2 = "26th enqueue argument
* X_MOLGA = ' ' "Fill argument 02 with initial value?
* X_FORML = ' ' "Fill argument 03 with initial value?
* MODE_T514V = 'E' "Lock mode for table T514V
* X_LGART = ' ' "Fill argument 04 with initial value?
* X_SPRSL = ' ' "Fill argument 05 with initial value?
* X_LGART2 = ' ' "Fill argument 06 with initial value?
* X_SPRSL2 = ' ' "Fill argument 07 with initial value?
* X_LTYPE = ' ' "Fill argument 08 with initial value?
* X_COLNO = ' ' "Fill argument 09 with initial value?
* X_FOFFS = ' ' "Fill argument 10 with initial value?
* X_LGART3 = ' ' "Fill argument 11 with initial value?
* X_TABNA = ' ' "Fill argument 12 with initial value?
* X_LFDNR = ' ' "Fill argument 13 with initial value?
* MODE_T512D = 'E' "Lock mode for table T512D
* X_WINDO = ' ' "Fill argument 14 with initial value?
* X_SPRSL3 = ' ' "Fill argument 15 with initial value?
* X_WINDO2 = ' ' "Fill argument 16 with initial value?
* X_GRPPE = ' ' "Fill argument 17 with initial value?
* X_KENNZ = ' ' "Fill argument 18 with initial value?
* X_LFDNR2 = ' ' "Fill argument 19 with initial value?
* X_REGEL = ' ' "Fill argument 20 with initial value?
* X_LFDNR3 = ' ' "Fill argument 21 with initial value?
* X_PTYPE = ' ' "Fill argument 22 with initial value?
* X_LINNO = ' ' "Fill argument 23 with initial value?
* MODE_T512E = 'E' "Lock mode for table T512E
* X_FOFFS2 = ' ' "Fill argument 24 with initial value?
* X_SPRSL4 = ' ' "Fill argument 25 with initial value?
* X_LINNO2 = ' ' "Fill argument 26 with initial value?
* _SCOPE = '3' "
* _SYNCHRON = ' ' "Synchonous unlock
* _COLLECT = ' ' "Initially only collect lock
* MODE_T512F = 'E' "Lock mode for table T512F
* MODE_T512G = 'E' "Lock mode for table T512G
* MODE_T512N = 'E' "Lock mode for table T512N
IMPORTING Parameters details for DEQUEUE_EPT514D
MODE_T514D - Lock mode for table T514D
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
MODE_T512Q - Lock mode for table T512Q
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
MODE_T512P - Lock mode for table T512P
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
MANDT - 01th enqueue argument
Data type: T514D-MANDTDefault: SY-MANDT
Optional: Yes
Call by Reference: No ( called with pass by value option)
MOLGA - 02th enqueue argument
Data type: T514D-MOLGAOptional: Yes
Call by Reference: No ( called with pass by value option)
FORML - 03th enqueue argument
Data type: T514D-FORMLOptional: Yes
Call by Reference: No ( called with pass by value option)
LGART - 04th enqueue argument
Data type: T512R-LGARTOptional: Yes
Call by Reference: No ( called with pass by value option)
SPRSL - 05th enqueue argument
Data type: T512S-SPRSLOptional: Yes
Call by Reference: No ( called with pass by value option)
LGART2 - 06th enqueue argument
Data type: T512S-LGARTOptional: Yes
Call by Reference: No ( called with pass by value option)
SPRSL2 - 07th enqueue argument
Data type: T514V-SPRSLOptional: Yes
Call by Reference: No ( called with pass by value option)
LTYPE - 08th enqueue argument
Data type: T512D-LTYPEOptional: Yes
Call by Reference: No ( called with pass by value option)
MODE_T512R - Lock mode for table T512R
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
COLNO - 09th enqueue argument
Data type: T512D-COLNOOptional: Yes
Call by Reference: No ( called with pass by value option)
FOFFS - 10th enqueue argument
Data type: T512D-FOFFSOptional: Yes
Call by Reference: No ( called with pass by value option)
LGART3 - 11th enqueue argument
Data type: T512E-LGARTOptional: Yes
Call by Reference: No ( called with pass by value option)
TABNA - 12th enqueue argument
Data type: T512E-TABNAOptional: Yes
Call by Reference: No ( called with pass by value option)
LFDNR - 13th enqueue argument
Data type: T512E-LFDNROptional: Yes
Call by Reference: No ( called with pass by value option)
WINDO - 14th enqueue argument
Data type: T512F-WINDOOptional: Yes
Call by Reference: No ( called with pass by value option)
SPRSL3 - 15th enqueue argument
Data type: T512G-SPRSLOptional: Yes
Call by Reference: No ( called with pass by value option)
WINDO2 - 16th enqueue argument
Data type: T512G-WINDOOptional: Yes
Call by Reference: No ( called with pass by value option)
GRPPE - 17th enqueue argument
Data type: T512G-GRPPEOptional: Yes
Call by Reference: No ( called with pass by value option)
KENNZ - 18th enqueue argument
Data type: T512G-KENNZOptional: Yes
Call by Reference: No ( called with pass by value option)
MODE_T512S - Lock mode for table T512S
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
LFDNR2 - 19th enqueue argument
Data type: T512G-LFDNROptional: Yes
Call by Reference: No ( called with pass by value option)
REGEL - 20th enqueue argument
Data type: T512N-REGELOptional: Yes
Call by Reference: No ( called with pass by value option)
LFDNR3 - 21th enqueue argument
Data type: T512N-LFDNROptional: Yes
Call by Reference: No ( called with pass by value option)
PTYPE - 22th enqueue argument
Data type: T512Q-PTYPEOptional: Yes
Call by Reference: No ( called with pass by value option)
LINNO - 23th enqueue argument
Data type: T512Q-LINNOOptional: Yes
Call by Reference: No ( called with pass by value option)
FOFFS2 - 24th enqueue argument
Data type: T512Q-FOFFSOptional: Yes
Call by Reference: No ( called with pass by value option)
SPRSL4 - 25th enqueue argument
Data type: T512P-SPRSLOptional: Yes
Call by Reference: No ( called with pass by value option)
LINNO2 - 26th enqueue argument
Data type: T512P-LINNOOptional: Yes
Call by Reference: No ( called with pass by value option)
X_MOLGA - Fill argument 02 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_FORML - Fill argument 03 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
MODE_T514V - Lock mode for table T514V
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_LGART - Fill argument 04 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_SPRSL - Fill argument 05 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_LGART2 - Fill argument 06 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_SPRSL2 - Fill argument 07 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_LTYPE - Fill argument 08 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_COLNO - Fill argument 09 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_FOFFS - Fill argument 10 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_LGART3 - Fill argument 11 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_TABNA - Fill argument 12 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_LFDNR - Fill argument 13 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
MODE_T512D - Lock mode for table T512D
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_WINDO - Fill argument 14 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_SPRSL3 - Fill argument 15 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_WINDO2 - Fill argument 16 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_GRPPE - Fill argument 17 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_KENNZ - Fill argument 18 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_LFDNR2 - Fill argument 19 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_REGEL - Fill argument 20 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_LFDNR3 - Fill argument 21 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_PTYPE - Fill argument 22 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_LINNO - Fill argument 23 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
MODE_T512E - Lock mode for table T512E
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_FOFFS2 - Fill argument 24 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_SPRSL4 - Fill argument 25 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
X_LINNO2 - Fill argument 26 with initial value?
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
_SCOPE -
Data type:Default: '3'
Optional: Yes
Call by Reference: No ( called with pass by value option)
_SYNCHRON - Synchonous unlock
Data type:Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)
_COLLECT - Initially only collect lock
Data type: DDENQCOLLDefault: ' '
Optional: Yes
Call by Reference: No ( called with pass by value option)
MODE_T512F - Lock mode for table T512F
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
MODE_T512G - Lock mode for table T512G
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
MODE_T512N - Lock mode for table T512N
Data type: ENQMODEDefault: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)
Copy and paste ABAP code example for DEQUEUE_EPT514D Function Module
The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.| DATA: | ||||
| lv_mode_t514d | TYPE ENQMODE, " 'E' | |||
| lv_mode_t512q | TYPE ENQMODE, " 'E' | |||
| lv_mode_t512p | TYPE ENQMODE, " 'E' | |||
| lv_mandt | TYPE T514D-MANDT, " SY-MANDT | |||
| lv_molga | TYPE T514D-MOLGA, " | |||
| lv_forml | TYPE T514D-FORML, " | |||
| lv_lgart | TYPE T512R-LGART, " | |||
| lv_sprsl | TYPE T512S-SPRSL, " | |||
| lv_lgart2 | TYPE T512S-LGART, " | |||
| lv_sprsl2 | TYPE T514V-SPRSL, " | |||
| lv_ltype | TYPE T512D-LTYPE, " | |||
| lv_mode_t512r | TYPE ENQMODE, " 'E' | |||
| lv_colno | TYPE T512D-COLNO, " | |||
| lv_foffs | TYPE T512D-FOFFS, " | |||
| lv_lgart3 | TYPE T512E-LGART, " | |||
| lv_tabna | TYPE T512E-TABNA, " | |||
| lv_lfdnr | TYPE T512E-LFDNR, " | |||
| lv_windo | TYPE T512F-WINDO, " | |||
| lv_sprsl3 | TYPE T512G-SPRSL, " | |||
| lv_windo2 | TYPE T512G-WINDO, " | |||
| lv_grppe | TYPE T512G-GRPPE, " | |||
| lv_kennz | TYPE T512G-KENNZ, " | |||
| lv_mode_t512s | TYPE ENQMODE, " 'E' | |||
| lv_lfdnr2 | TYPE T512G-LFDNR, " | |||
| lv_regel | TYPE T512N-REGEL, " | |||
| lv_lfdnr3 | TYPE T512N-LFDNR, " | |||
| lv_ptype | TYPE T512Q-PTYPE, " | |||
| lv_linno | TYPE T512Q-LINNO, " | |||
| lv_foffs2 | TYPE T512Q-FOFFS, " | |||
| lv_sprsl4 | TYPE T512P-SPRSL, " | |||
| lv_linno2 | TYPE T512P-LINNO, " | |||
| lv_x_molga | TYPE T512P, " SPACE | |||
| lv_x_forml | TYPE T512P, " SPACE | |||
| lv_mode_t514v | TYPE ENQMODE, " 'E' | |||
| lv_x_lgart | TYPE ENQMODE, " SPACE | |||
| lv_x_sprsl | TYPE ENQMODE, " SPACE | |||
| lv_x_lgart2 | TYPE ENQMODE, " SPACE | |||
| lv_x_sprsl2 | TYPE ENQMODE, " SPACE | |||
| lv_x_ltype | TYPE ENQMODE, " SPACE | |||
| lv_x_colno | TYPE ENQMODE, " SPACE | |||
| lv_x_foffs | TYPE ENQMODE, " SPACE | |||
| lv_x_lgart3 | TYPE ENQMODE, " SPACE | |||
| lv_x_tabna | TYPE ENQMODE, " SPACE | |||
| lv_x_lfdnr | TYPE ENQMODE, " SPACE | |||
| lv_mode_t512d | TYPE ENQMODE, " 'E' | |||
| lv_x_windo | TYPE ENQMODE, " SPACE | |||
| lv_x_sprsl3 | TYPE ENQMODE, " SPACE | |||
| lv_x_windo2 | TYPE ENQMODE, " SPACE | |||
| lv_x_grppe | TYPE ENQMODE, " SPACE | |||
| lv_x_kennz | TYPE ENQMODE, " SPACE | |||
| lv_x_lfdnr2 | TYPE ENQMODE, " SPACE | |||
| lv_x_regel | TYPE ENQMODE, " SPACE | |||
| lv_x_lfdnr3 | TYPE ENQMODE, " SPACE | |||
| lv_x_ptype | TYPE ENQMODE, " SPACE | |||
| lv_x_linno | TYPE ENQMODE, " SPACE | |||
| lv_mode_t512e | TYPE ENQMODE, " 'E' | |||
| lv_x_foffs2 | TYPE ENQMODE, " SPACE | |||
| lv_x_sprsl4 | TYPE ENQMODE, " SPACE | |||
| lv_x_linno2 | TYPE ENQMODE, " SPACE | |||
| lv__scope | TYPE ENQMODE, " '3' | |||
| lv__synchron | TYPE ENQMODE, " SPACE | |||
| lv__collect | TYPE DDENQCOLL, " ' ' | |||
| lv_mode_t512f | TYPE ENQMODE, " 'E' | |||
| lv_mode_t512g | TYPE ENQMODE, " 'E' | |||
| lv_mode_t512n | TYPE ENQMODE. " 'E' |
|   CALL FUNCTION 'DEQUEUE_EPT514D' "Release lock on object EPT514D |
| EXPORTING | ||
| MODE_T514D | = lv_mode_t514d | |
| MODE_T512Q | = lv_mode_t512q | |
| MODE_T512P | = lv_mode_t512p | |
| MANDT | = lv_mandt | |
| MOLGA | = lv_molga | |
| FORML | = lv_forml | |
| LGART | = lv_lgart | |
| SPRSL | = lv_sprsl | |
| LGART2 | = lv_lgart2 | |
| SPRSL2 | = lv_sprsl2 | |
| LTYPE | = lv_ltype | |
| MODE_T512R | = lv_mode_t512r | |
| COLNO | = lv_colno | |
| FOFFS | = lv_foffs | |
| LGART3 | = lv_lgart3 | |
| TABNA | = lv_tabna | |
| LFDNR | = lv_lfdnr | |
| WINDO | = lv_windo | |
| SPRSL3 | = lv_sprsl3 | |
| WINDO2 | = lv_windo2 | |
| GRPPE | = lv_grppe | |
| KENNZ | = lv_kennz | |
| MODE_T512S | = lv_mode_t512s | |
| LFDNR2 | = lv_lfdnr2 | |
| REGEL | = lv_regel | |
| LFDNR3 | = lv_lfdnr3 | |
| PTYPE | = lv_ptype | |
| LINNO | = lv_linno | |
| FOFFS2 | = lv_foffs2 | |
| SPRSL4 | = lv_sprsl4 | |
| LINNO2 | = lv_linno2 | |
| X_MOLGA | = lv_x_molga | |
| X_FORML | = lv_x_forml | |
| MODE_T514V | = lv_mode_t514v | |
| X_LGART | = lv_x_lgart | |
| X_SPRSL | = lv_x_sprsl | |
| X_LGART2 | = lv_x_lgart2 | |
| X_SPRSL2 | = lv_x_sprsl2 | |
| X_LTYPE | = lv_x_ltype | |
| X_COLNO | = lv_x_colno | |
| X_FOFFS | = lv_x_foffs | |
| X_LGART3 | = lv_x_lgart3 | |
| X_TABNA | = lv_x_tabna | |
| X_LFDNR | = lv_x_lfdnr | |
| MODE_T512D | = lv_mode_t512d | |
| X_WINDO | = lv_x_windo | |
| X_SPRSL3 | = lv_x_sprsl3 | |
| X_WINDO2 | = lv_x_windo2 | |
| X_GRPPE | = lv_x_grppe | |
| X_KENNZ | = lv_x_kennz | |
| X_LFDNR2 | = lv_x_lfdnr2 | |
| X_REGEL | = lv_x_regel | |
| X_LFDNR3 | = lv_x_lfdnr3 | |
| X_PTYPE | = lv_x_ptype | |
| X_LINNO | = lv_x_linno | |
| MODE_T512E | = lv_mode_t512e | |
| X_FOFFS2 | = lv_x_foffs2 | |
| X_SPRSL4 | = lv_x_sprsl4 | |
| X_LINNO2 | = lv_x_linno2 | |
| _SCOPE | = lv__scope | |
| _SYNCHRON | = lv__synchron | |
| _COLLECT | = lv__collect | |
| MODE_T512F | = lv_mode_t512f | |
| MODE_T512G | = lv_mode_t512g | |
| MODE_T512N | = lv_mode_t512n | |
| . " DEQUEUE_EPT514D | ||
ABAP code using 7.40 inline data declarations to call FM DEQUEUE_EPT514D
The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.| DATA(ld_mode_t514d) | = 'E'. | |||
| DATA(ld_mode_t512q) | = 'E'. | |||
| DATA(ld_mode_t512p) | = 'E'. | |||
| "SELECT single MANDT FROM T514D INTO @DATA(ld_mandt). | ||||
| DATA(ld_mandt) | = SY-MANDT. | |||
| "SELECT single MOLGA FROM T514D INTO @DATA(ld_molga). | ||||
| "SELECT single FORML FROM T514D INTO @DATA(ld_forml). | ||||
| "SELECT single LGART FROM T512R INTO @DATA(ld_lgart). | ||||
| "SELECT single SPRSL FROM T512S INTO @DATA(ld_sprsl). | ||||
| "SELECT single LGART FROM T512S INTO @DATA(ld_lgart2). | ||||
| "SELECT single SPRSL FROM T514V INTO @DATA(ld_sprsl2). | ||||
| "SELECT single LTYPE FROM T512D INTO @DATA(ld_ltype). | ||||
| DATA(ld_mode_t512r) | = 'E'. | |||
| "SELECT single COLNO FROM T512D INTO @DATA(ld_colno). | ||||
| "SELECT single FOFFS FROM T512D INTO @DATA(ld_foffs). | ||||
| "SELECT single LGART FROM T512E INTO @DATA(ld_lgart3). | ||||
| "SELECT single TABNA FROM T512E INTO @DATA(ld_tabna). | ||||
| "SELECT single LFDNR FROM T512E INTO @DATA(ld_lfdnr). | ||||
| "SELECT single WINDO FROM T512F INTO @DATA(ld_windo). | ||||
| "SELECT single SPRSL FROM T512G INTO @DATA(ld_sprsl3). | ||||
| "SELECT single WINDO FROM T512G INTO @DATA(ld_windo2). | ||||
| "SELECT single GRPPE FROM T512G INTO @DATA(ld_grppe). | ||||
| "SELECT single KENNZ FROM T512G INTO @DATA(ld_kennz). | ||||
| DATA(ld_mode_t512s) | = 'E'. | |||
| "SELECT single LFDNR FROM T512G INTO @DATA(ld_lfdnr2). | ||||
| "SELECT single REGEL FROM T512N INTO @DATA(ld_regel). | ||||
| "SELECT single LFDNR FROM T512N INTO @DATA(ld_lfdnr3). | ||||
| "SELECT single PTYPE FROM T512Q INTO @DATA(ld_ptype). | ||||
| "SELECT single LINNO FROM T512Q INTO @DATA(ld_linno). | ||||
| "SELECT single FOFFS FROM T512Q INTO @DATA(ld_foffs2). | ||||
| "SELECT single SPRSL FROM T512P INTO @DATA(ld_sprsl4). | ||||
| "SELECT single LINNO FROM T512P INTO @DATA(ld_linno2). | ||||
| DATA(ld_x_molga) | = ' '. | |||
| DATA(ld_x_forml) | = ' '. | |||
| DATA(ld_mode_t514v) | = 'E'. | |||
| DATA(ld_x_lgart) | = ' '. | |||
| DATA(ld_x_sprsl) | = ' '. | |||
| DATA(ld_x_lgart2) | = ' '. | |||
| DATA(ld_x_sprsl2) | = ' '. | |||
| DATA(ld_x_ltype) | = ' '. | |||
| DATA(ld_x_colno) | = ' '. | |||
| DATA(ld_x_foffs) | = ' '. | |||
| DATA(ld_x_lgart3) | = ' '. | |||
| DATA(ld_x_tabna) | = ' '. | |||
| DATA(ld_x_lfdnr) | = ' '. | |||
| DATA(ld_mode_t512d) | = 'E'. | |||
| DATA(ld_x_windo) | = ' '. | |||
| DATA(ld_x_sprsl3) | = ' '. | |||
| DATA(ld_x_windo2) | = ' '. | |||
| DATA(ld_x_grppe) | = ' '. | |||
| DATA(ld_x_kennz) | = ' '. | |||
| DATA(ld_x_lfdnr2) | = ' '. | |||
| DATA(ld_x_regel) | = ' '. | |||
| DATA(ld_x_lfdnr3) | = ' '. | |||
| DATA(ld_x_ptype) | = ' '. | |||
| DATA(ld_x_linno) | = ' '. | |||
| DATA(ld_mode_t512e) | = 'E'. | |||
| DATA(ld_x_foffs2) | = ' '. | |||
| DATA(ld_x_sprsl4) | = ' '. | |||
| DATA(ld_x_linno2) | = ' '. | |||
| DATA(ld__scope) | = '3'. | |||
| DATA(ld__synchron) | = ' '. | |||
| DATA(ld__collect) | = ' '. | |||
| DATA(ld_mode_t512f) | = 'E'. | |||
| DATA(ld_mode_t512g) | = 'E'. | |||
| DATA(ld_mode_t512n) | = 'E'. | |||
Search for further information about these or an SAP related objects