SAP DEQUEUE_EPIC_BC_UA Function Module for Release lock on object EPIC_BC_UA









DEQUEUE_EPIC_BC_UA is a standard dequeue epic bc ua SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used for Release lock on object EPIC_BC_UA processing and below is the pattern details for this FM, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.


See here to view full function module documentation and code listing for dequeue epic bc ua FM, simply by entering the name DEQUEUE_EPIC_BC_UA into the relevant SAP transaction such as SE37 or SE38.

Function Group: /1BCDWBEN/IEN0002
Program Name: /1BCDWBEN/SAPLIEN0002
Main Program:
Appliation area:
Release date: N/A
Mode(Normal, Remote etc): Normal Function Module
Update:



Function DEQUEUE_EPIC_BC_UA pattern details

In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.
CALL FUNCTION 'DEQUEUE_EPIC_BC_UA'"Release lock on object EPIC_BC_UA
EXPORTING
* MODE_EPIC_BC_UA = 'E' "Lock mode for table EPIC_BC_UA
* X_HKTID = ' ' "Fill argument 04 with initial value?
* X_BCTYP = ' ' "Fill argument 05 with initial value?
* X_COMSTP = ' ' "Fill argument 06 with initial value?
* _SCOPE = '3' "
* _SYNCHRON = ' ' "Synchonous unlock
* _COLLECT = ' ' "Initially only collect lock
* MANDT = SY-MANDT "01th enqueue argument
* ZBUKR = "02th enqueue argument
* HBKID = "03th enqueue argument
* HKTID = "04th enqueue argument
* BCTYP = "05th enqueue argument
* COMSTP = "06th enqueue argument
* X_ZBUKR = ' ' "Fill argument 02 with initial value?
* X_HBKID = ' ' "Fill argument 03 with initial value?
.



IMPORTING Parameters details for DEQUEUE_EPIC_BC_UA

MODE_EPIC_BC_UA - Lock mode for table EPIC_BC_UA

Data type: ENQMODE
Default: 'E'
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_HKTID - Fill argument 04 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_BCTYP - Fill argument 05 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_COMSTP - Fill argument 06 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

_SCOPE -

Data type:
Default: '3'
Optional: Yes
Call by Reference: No ( called with pass by value option)

_SYNCHRON - Synchonous unlock

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

_COLLECT - Initially only collect lock

Data type: DDENQCOLL
Default: ' '
Optional: Yes
Call by Reference: No ( called with pass by value option)

MANDT - 01th enqueue argument

Data type: EPIC_BC_UA-MANDT
Default: SY-MANDT
Optional: Yes
Call by Reference: No ( called with pass by value option)

ZBUKR - 02th enqueue argument

Data type: EPIC_BC_UA-ZBUKR
Optional: Yes
Call by Reference: No ( called with pass by value option)

HBKID - 03th enqueue argument

Data type: EPIC_BC_UA-HBKID
Optional: Yes
Call by Reference: No ( called with pass by value option)

HKTID - 04th enqueue argument

Data type: EPIC_BC_UA-HKTID
Optional: Yes
Call by Reference: No ( called with pass by value option)

BCTYP - 05th enqueue argument

Data type: EPIC_BC_UA-BCTYP
Optional: Yes
Call by Reference: No ( called with pass by value option)

COMSTP - 06th enqueue argument

Data type: EPIC_BC_UA-COMSTP
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_ZBUKR - Fill argument 02 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

X_HBKID - Fill argument 03 with initial value?

Data type:
Default: SPACE
Optional: Yes
Call by Reference: No ( called with pass by value option)

Copy and paste ABAP code example for DEQUEUE_EPIC_BC_UA Function Module

The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.

DATA:
lv_mode_epic_bc_ua  TYPE ENQMODE, "   'E'
lv_x_hktid  TYPE ENQMODE, "   SPACE
lv_x_bctyp  TYPE ENQMODE, "   SPACE
lv_x_comstp  TYPE ENQMODE, "   SPACE
lv__scope  TYPE ENQMODE, "   '3'
lv__synchron  TYPE ENQMODE, "   SPACE
lv__collect  TYPE DDENQCOLL, "   ' '
lv_mandt  TYPE EPIC_BC_UA-MANDT, "   SY-MANDT
lv_zbukr  TYPE EPIC_BC_UA-ZBUKR, "   
lv_hbkid  TYPE EPIC_BC_UA-HBKID, "   
lv_hktid  TYPE EPIC_BC_UA-HKTID, "   
lv_bctyp  TYPE EPIC_BC_UA-BCTYP, "   
lv_comstp  TYPE EPIC_BC_UA-COMSTP, "   
lv_x_zbukr  TYPE EPIC_BC_UA, "   SPACE
lv_x_hbkid  TYPE EPIC_BC_UA. "   SPACE

  CALL FUNCTION 'DEQUEUE_EPIC_BC_UA'  "Release lock on object EPIC_BC_UA
    EXPORTING
         MODE_EPIC_BC_UA = lv_mode_epic_bc_ua
         X_HKTID = lv_x_hktid
         X_BCTYP = lv_x_bctyp
         X_COMSTP = lv_x_comstp
         _SCOPE = lv__scope
         _SYNCHRON = lv__synchron
         _COLLECT = lv__collect
         MANDT = lv_mandt
         ZBUKR = lv_zbukr
         HBKID = lv_hbkid
         HKTID = lv_hktid
         BCTYP = lv_bctyp
         COMSTP = lv_comstp
         X_ZBUKR = lv_x_zbukr
         X_HBKID = lv_x_hbkid
. " DEQUEUE_EPIC_BC_UA




ABAP code using 7.40 inline data declarations to call FM DEQUEUE_EPIC_BC_UA

The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.

DATA(ld_mode_epic_bc_ua) = 'E'.
 
DATA(ld_x_hktid) = ' '.
 
DATA(ld_x_bctyp) = ' '.
 
DATA(ld_x_comstp) = ' '.
 
DATA(ld__scope) = '3'.
 
DATA(ld__synchron) = ' '.
 
DATA(ld__collect) = ' '.
 
"SELECT single MANDT FROM EPIC_BC_UA INTO @DATA(ld_mandt).
DATA(ld_mandt) = SY-MANDT.
 
"SELECT single ZBUKR FROM EPIC_BC_UA INTO @DATA(ld_zbukr).
 
"SELECT single HBKID FROM EPIC_BC_UA INTO @DATA(ld_hbkid).
 
"SELECT single HKTID FROM EPIC_BC_UA INTO @DATA(ld_hktid).
 
"SELECT single BCTYP FROM EPIC_BC_UA INTO @DATA(ld_bctyp).
 
"SELECT single COMSTP FROM EPIC_BC_UA INTO @DATA(ld_comstp).
 
DATA(ld_x_zbukr) = ' '.
 
DATA(ld_x_hbkid) = ' '.
 


Search for further information about these or an SAP related objects



Comments on this SAP object

What made you want to lookup this SAP object? Please tell us what you were looking for and anything you would like to be included on this page!