SAP C14O_CD_OBJECTS_READ_OLD Function Module for NOTRANSL: EHS: Lesen der Änderungsbelegobjekte von der Datenbank
C14O_CD_OBJECTS_READ_OLD is a standard c14o cd objects read old SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used for NOTRANSL: EHS: Lesen der Änderungsbelegobjekte von der Datenbank processing and below is the pattern details for this FM, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.
See here to view full function module documentation and code listing for c14o cd objects read old FM, simply by entering the name C14O_CD_OBJECTS_READ_OLD into the relevant SAP transaction such as SE37 or SE38.
Function Group: C14O
Program Name: SAPLC14O
Main Program: SAPLC14O
Appliation area: S
Release date: N/A
Mode(Normal, Remote etc): Normal Function Module
Update:

Function C14O_CD_OBJECTS_READ_OLD pattern details
In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.CALL FUNCTION 'C14O_CD_OBJECTS_READ_OLD'"NOTRANSL: EHS: Lesen der Änderungsbelegobjekte von der Datenbank.
EXPORTING
I_TABLENAME = "
I_VALFROM = "
I_VALTO = "
* I_OBJECT = "
TABLES
I_OBJECT_TAB = "
E_CD_HEADER_TAB = "
E_CD_POSITION_TAB = "
IMPORTING Parameters details for C14O_CD_OBJECTS_READ_OLD
I_TABLENAME -
Data type: ESP1_TAB_NAMEOptional: No
Call by Reference: No ( called with pass by value option)
I_VALFROM -
Data type: SY-DATUMOptional: No
Call by Reference: No ( called with pass by value option)
I_VALTO -
Data type: SY-DATUMOptional: No
Call by Reference: No ( called with pass by value option)
I_OBJECT -
Data type: CDHDR-OBJECTIDOptional: Yes
Call by Reference: No ( called with pass by value option)
TABLES Parameters details for C14O_CD_OBJECTS_READ_OLD
I_OBJECT_TAB -
Data type: CDKEYTABOptional: No
Call by Reference: No ( called with pass by value option)
E_CD_HEADER_TAB -
Data type: CDHDROptional: No
Call by Reference: No ( called with pass by value option)
E_CD_POSITION_TAB -
Data type: CDSHWOptional: No
Call by Reference: No ( called with pass by value option)
Copy and paste ABAP code example for C14O_CD_OBJECTS_READ_OLD Function Module
The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.| DATA: | ||||
| lv_i_tablename | TYPE ESP1_TAB_NAME, " | |||
| lt_i_object_tab | TYPE STANDARD TABLE OF CDKEYTAB, " | |||
| lv_i_valfrom | TYPE SY-DATUM, " | |||
| lt_e_cd_header_tab | TYPE STANDARD TABLE OF CDHDR, " | |||
| lv_i_valto | TYPE SY-DATUM, " | |||
| lt_e_cd_position_tab | TYPE STANDARD TABLE OF CDSHW, " | |||
| lv_i_object | TYPE CDHDR-OBJECTID. " |
|   CALL FUNCTION 'C14O_CD_OBJECTS_READ_OLD' "NOTRANSL: EHS: Lesen der Änderungsbelegobjekte von der Datenbank |
| EXPORTING | ||
| I_TABLENAME | = lv_i_tablename | |
| I_VALFROM | = lv_i_valfrom | |
| I_VALTO | = lv_i_valto | |
| I_OBJECT | = lv_i_object | |
| TABLES | ||
| I_OBJECT_TAB | = lt_i_object_tab | |
| E_CD_HEADER_TAB | = lt_e_cd_header_tab | |
| E_CD_POSITION_TAB | = lt_e_cd_position_tab | |
| . " C14O_CD_OBJECTS_READ_OLD | ||
ABAP code using 7.40 inline data declarations to call FM C14O_CD_OBJECTS_READ_OLD
The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.| "SELECT single DATUM FROM SY INTO @DATA(ld_i_valfrom). | ||||
| "SELECT single DATUM FROM SY INTO @DATA(ld_i_valto). | ||||
| "SELECT single OBJECTID FROM CDHDR INTO @DATA(ld_i_object). | ||||
Search for further information about these or an SAP related objects