SAP C107TS_ENTRY Function Module for









C107TS_ENTRY is a standard c107ts entry SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used to perform a specific ABAP function and below is the pattern details, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.


See here to view full function module documentation and code listing for c107ts entry FM, simply by entering the name C107TS_ENTRY into the relevant SAP transaction such as SE37 or SE38.

Function Group: C107TS
Program Name: SAPLC107TS
Main Program: SAPLC107TS
Appliation area: M
Release date: N/A
Mode(Normal, Remote etc): Normal Function Module
Update:



Function C107TS_ENTRY pattern details

In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.
CALL FUNCTION 'C107TS_ENTRY'"
EXPORTING
I_ACTYPE = "Current Activity Type
I_TRTYPE = "Current Transaction Type
I_KEYPATH = "
I_ADDINF = "Additional information
* I_RECNTVA = "Sequential Number of Data Record
* I_CUA_SET_FUNC = 'C101_CUA_SET' "
* I_FLG_REF_ALLOWED = ESP1_TRUE "
* I_FLG_SIN_INST_POP = ESP1_FALSE "
* I_FLG_SUBSCR_CALL = ESP1_FALSE "

IMPORTING
E_FLG_CHANGED = "
E_OKCODE = "
E_DYNNR = "ABAP Program, Current Screen Number
E_REPID = "
E_ACTYPE = "Activity Type in the Transaction
E_KEYPATH = "EHS: 'Key' path substance/list/property for FM call

EXCEPTIONS
REFERENCE_CONFLICT = 1 NO_AUTHORITY = 2 SUBST_UPD_FIELDS_SET_ERROR = 3 CONVMODE_SET_FAILED = 4
.



IMPORTING Parameters details for C107TS_ENTRY

I_ACTYPE - Current Activity Type

Data type: RCGDIALCTR-ACTYPE
Optional: No
Call by Reference: No ( called with pass by value option)

I_TRTYPE - Current Transaction Type

Data type: RCGDIALCTR-TRTYPE
Optional: No
Call by Reference: No ( called with pass by value option)

I_KEYPATH -

Data type: RCGKPATH
Optional: No
Call by Reference: No ( called with pass by value option)

I_ADDINF - Additional information

Data type: RCGADDINF
Optional: No
Call by Reference: No ( called with pass by value option)

I_RECNTVA - Sequential Number of Data Record

Data type: ESERECN
Optional: Yes
Call by Reference: No ( called with pass by value option)

I_CUA_SET_FUNC -

Data type: TFDIR-FUNCNAME
Default: 'C101_CUA_SET'
Optional: Yes
Call by Reference: No ( called with pass by value option)

I_FLG_REF_ALLOWED -

Data type: ESP1_BOOLEAN
Default: ESP1_TRUE
Optional: Yes
Call by Reference: No ( called with pass by value option)

I_FLG_SIN_INST_POP -

Data type: ESP1_BOOLEAN
Default: ESP1_FALSE
Optional: Yes
Call by Reference: No ( called with pass by value option)

I_FLG_SUBSCR_CALL -

Data type: ESP1_BOOLEAN
Default: ESP1_FALSE
Optional: Yes
Call by Reference: No ( called with pass by value option)

EXPORTING Parameters details for C107TS_ENTRY

E_FLG_CHANGED -

Data type: ESP1_BOOLEAN
Optional: No
Call by Reference: No ( called with pass by value option)

E_OKCODE -

Data type: ESP1_OKCODE_TYPE
Optional: No
Call by Reference: No ( called with pass by value option)

E_DYNNR - ABAP Program, Current Screen Number

Data type: SY-DYNNR
Optional: No
Call by Reference: No ( called with pass by value option)

E_REPID -

Data type: SY-REPID
Optional: No
Call by Reference: No ( called with pass by value option)

E_ACTYPE - Activity Type in the Transaction

Data type: RCGDIALCTR-ACTYPE
Optional: No
Call by Reference: No ( called with pass by value option)

E_KEYPATH - EHS: 'Key' path substance/list/property for FM call

Data type: RCGKPATH
Optional: No
Call by Reference: No ( called with pass by value option)

EXCEPTIONS details

REFERENCE_CONFLICT -

Data type:
Optional: No
Call by Reference: No ( called with pass by value option)

NO_AUTHORITY - No Authorization

Data type:
Optional: No
Call by Reference: No ( called with pass by value option)

SUBST_UPD_FIELDS_SET_ERROR -

Data type:
Optional: No
Call by Reference: No ( called with pass by value option)

CONVMODE_SET_FAILED -

Data type:
Optional: No
Call by Reference: No ( called with pass by value option)

Copy and paste ABAP code example for C107TS_ENTRY Function Module

The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.

DATA:
lv_i_actype  TYPE RCGDIALCTR-ACTYPE, "   
lv_e_flg_changed  TYPE ESP1_BOOLEAN, "   
lv_reference_conflict  TYPE ESP1_BOOLEAN, "   
lv_e_okcode  TYPE ESP1_OKCODE_TYPE, "   
lv_i_trtype  TYPE RCGDIALCTR-TRTYPE, "   
lv_no_authority  TYPE RCGDIALCTR, "   
lv_e_dynnr  TYPE SY-DYNNR, "   
lv_i_keypath  TYPE RCGKPATH, "   
lv_subst_upd_fields_set_error  TYPE RCGKPATH, "   
lv_e_repid  TYPE SY-REPID, "   
lv_i_addinf  TYPE RCGADDINF, "   
lv_convmode_set_failed  TYPE RCGADDINF, "   
lv_e_actype  TYPE RCGDIALCTR-ACTYPE, "   
lv_i_recntva  TYPE ESERECN, "   
lv_e_keypath  TYPE RCGKPATH, "   
lv_i_cua_set_func  TYPE TFDIR-FUNCNAME, "   'C101_CUA_SET'
lv_i_flg_ref_allowed  TYPE ESP1_BOOLEAN, "   ESP1_TRUE
lv_i_flg_sin_inst_pop  TYPE ESP1_BOOLEAN, "   ESP1_FALSE
lv_i_flg_subscr_call  TYPE ESP1_BOOLEAN. "   ESP1_FALSE

  CALL FUNCTION 'C107TS_ENTRY'  "
    EXPORTING
         I_ACTYPE = lv_i_actype
         I_TRTYPE = lv_i_trtype
         I_KEYPATH = lv_i_keypath
         I_ADDINF = lv_i_addinf
         I_RECNTVA = lv_i_recntva
         I_CUA_SET_FUNC = lv_i_cua_set_func
         I_FLG_REF_ALLOWED = lv_i_flg_ref_allowed
         I_FLG_SIN_INST_POP = lv_i_flg_sin_inst_pop
         I_FLG_SUBSCR_CALL = lv_i_flg_subscr_call
    IMPORTING
         E_FLG_CHANGED = lv_e_flg_changed
         E_OKCODE = lv_e_okcode
         E_DYNNR = lv_e_dynnr
         E_REPID = lv_e_repid
         E_ACTYPE = lv_e_actype
         E_KEYPATH = lv_e_keypath
    EXCEPTIONS
        REFERENCE_CONFLICT = 1
        NO_AUTHORITY = 2
        SUBST_UPD_FIELDS_SET_ERROR = 3
        CONVMODE_SET_FAILED = 4
. " C107TS_ENTRY




ABAP code using 7.40 inline data declarations to call FM C107TS_ENTRY

The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.

"SELECT single ACTYPE FROM RCGDIALCTR INTO @DATA(ld_i_actype).
 
 
 
 
"SELECT single TRTYPE FROM RCGDIALCTR INTO @DATA(ld_i_trtype).
 
 
"SELECT single DYNNR FROM SY INTO @DATA(ld_e_dynnr).
 
 
 
"SELECT single REPID FROM SY INTO @DATA(ld_e_repid).
 
 
 
"SELECT single ACTYPE FROM RCGDIALCTR INTO @DATA(ld_e_actype).
 
 
 
"SELECT single FUNCNAME FROM TFDIR INTO @DATA(ld_i_cua_set_func).
DATA(ld_i_cua_set_func) = 'C101_CUA_SET'.
 
DATA(ld_i_flg_ref_allowed) = ESP1_TRUE.
 
DATA(ld_i_flg_sin_inst_pop) = ESP1_FALSE.
 
DATA(ld_i_flg_subscr_call) = ESP1_FALSE.
 


Search for further information about these or an SAP related objects



Comments on this SAP object

What made you want to lookup this SAP object? Please tell us what you were looking for and anything you would like to be included on this page!