SAP /BKC/RFC_INSERT_PD_INFTY Function Module for C&T! - Insert of PD infotypes
/BKC/RFC_INSERT_PD_INFTY is a standard /bkc/rfc insert pd infty SAP function module available within SAP R/3 or S/4 Hana systems, depending on your version and release level. It is used for C&T! - Insert of PD infotypes processing and below is the pattern details for this FM, showing its interface including any import and export parameters, exceptions etc. there is also a full "cut and paste" ABAP pattern code example, along with implementation ABAP coding, documentation and contribution comments specific to this or related objects.
See here to view full function module documentation and code listing for /bkc/rfc insert pd infty FM, simply by entering the name /BKC/RFC_INSERT_PD_INFTY into the relevant SAP transaction such as SE37 or SE38.
Function Group: /BKC/SOL21
Program Name: /BKC/SAPLSOL21
Main Program: /BKC/SAPLSOL21
Appliation area:
Release date: N/A
Mode(Normal, Remote etc): Remote-Enabled
Update:

Function /BKC/RFC_INSERT_PD_INFTY pattern details
In-order to call this FM within your sap programs, simply using the below ABAP pattern details to trigger the function call...or see the full ABAP code listing at the end of this article. You can simply cut and paste this code into your ABAP progrom as it is, including variable declarations.CALL FUNCTION '/BKC/RFC_INSERT_PD_INFTY'"C&T! - Insert of PD infotypes.
EXPORTING
* COMPRESS_I = "Background processing, program running in the background
* XBUFNAME_TINFTY = "Table name
* COMPRESS_T = "Background processing, program running in the background
TABNAME_I = "Table name
TABNAME_T = "Table name
* CALLER_IS_UNICODE = "Background processing, program running in the background
* IF_VERSN = '01' "Version of cluster data
* XBUFSIZE_INFTY = 4096 "C&T! - Size of binary buffer
* XBUFSIZE_TINFTY = 2048 "C&T! - Size of binary buffer
* XBUFNAME_INFTY = "Table name
IMPORTING
RC = "Return value, return value according to ABAP instructions
TABLE_DOES_NOT_EXIST = "Background processing, program running in the background
TABLES
* HRBUFFER_P = "C&T! - Transfer buffer for PD infotypes + personnel number
* INFTY_XBUFFER512 = "C&T! - Binary buffer with 512 byte
* INFTY_XBUFFER1024 = "C&T! - Binary buffer with 1024 byte
* INFTY_XBUFFER2048 = "C&T! - Binary buffer with 2048 byte
* INFTY_XBUFFER4096 = "C&T! - Binary buffer with 4096 byte
* INFTY_XBUFFER8192 = "C&T! - Binary buffer with 8192 byte
* INFTY_XBUFFER16384 = "C&T! - Binary buffer with 16384 byte
* TINFTY_XBUFFER32 = "C&T! - Binary buffer with 32 byte
* TINFTY_XBUFFER64 = "C&T! - Binary buffer with 64 byte
* TINFTY_XBUFFER128 = "C&T! - Binary buffer with 128 bytes
* TINFTY_XBUFFER256 = "C&T! - Binary buffer with 256 byte
* HRTBUFFER_P = "C&T! - Buffer for PD infotype tables + personnel number
* TINFTY_XBUFFER512 = "C&T! - Binary buffer with 512 byte
* TINFTY_XBUFFER1024 = "C&T! - Binary buffer with 1024 byte
* TINFTY_XBUFFER2048 = "C&T! - Binary buffer with 2048 byte
* TINFTY_XBUFFER4096 = "C&T! - Binary buffer with 4096 byte
* TINFTY_XBUFFER8192 = "C&T! - Binary buffer with 8192 byte
* TINFTY_XBUFFER16384 = "C&T! - Binary buffer with 16384 byte
* PTAB1 = "C&T! - Assignment old -> new personnel numbers
* PTAB2 = "C&T! - Assignment old -> new personnel numbers
* SYS_FEHLER = "C&T! - Interface structure for error messages
* INFTY_XBUFFER32 = "C&T! - Binary buffer with 32 byte
* INFTY_XBUFFER64 = "C&T! - Binary buffer with 64 byte
* INFTY_XBUFFER128 = "C&T! - Binary buffer with 128 bytes
* INFTY_XBUFFER256 = "C&T! - Binary buffer with 256 byte
IMPORTING Parameters details for /BKC/RFC_INSERT_PD_INFTY
COMPRESS_I - Background processing, program running in the background
Data type: SY-BATCHOptional: Yes
Call by Reference: No ( called with pass by value option)
XBUFNAME_TINFTY - Table name
Data type: TABNAMEOptional: Yes
Call by Reference: No ( called with pass by value option)
COMPRESS_T - Background processing, program running in the background
Data type: SY-BATCHOptional: Yes
Call by Reference: No ( called with pass by value option)
TABNAME_I - Table name
Data type: TABNAMEOptional: No
Call by Reference: No ( called with pass by value option)
TABNAME_T - Table name
Data type: TABNAMEOptional: No
Call by Reference: No ( called with pass by value option)
CALLER_IS_UNICODE - Background processing, program running in the background
Data type: SY-BATCHOptional: Yes
Call by Reference: No ( called with pass by value option)
IF_VERSN - Version of cluster data
Data type: PVRSNDefault: '01'
Optional: Yes
Call by Reference: No ( called with pass by value option)
XBUFSIZE_INFTY - C&T! - Size of binary buffer
Data type: /BKC/S21_XBUFSIZEDefault: 4096
Optional: Yes
Call by Reference: No ( called with pass by value option)
XBUFSIZE_TINFTY - C&T! - Size of binary buffer
Data type: /BKC/S21_XBUFSIZEDefault: 2048
Optional: Yes
Call by Reference: No ( called with pass by value option)
XBUFNAME_INFTY - Table name
Data type: TABNAMEOptional: Yes
Call by Reference: No ( called with pass by value option)
EXPORTING Parameters details for /BKC/RFC_INSERT_PD_INFTY
RC - Return value, return value according to ABAP instructions
Data type: SY-SUBRCOptional: No
Call by Reference: No ( called with pass by value option)
TABLE_DOES_NOT_EXIST - Background processing, program running in the background
Data type: SY-BATCHOptional: No
Call by Reference: No ( called with pass by value option)
TABLES Parameters details for /BKC/RFC_INSERT_PD_INFTY
HRBUFFER_P - C&T! - Transfer buffer for PD infotypes + personnel number
Data type: /BKC/S21_HRBUFFER_POptional: Yes
Call by Reference: Yes
INFTY_XBUFFER512 - C&T! - Binary buffer with 512 byte
Data type: /BKC/S21_XBUF512Optional: Yes
Call by Reference: Yes
INFTY_XBUFFER1024 - C&T! - Binary buffer with 1024 byte
Data type: /BKC/S21_XBUF1024Optional: Yes
Call by Reference: Yes
INFTY_XBUFFER2048 - C&T! - Binary buffer with 2048 byte
Data type: /BKC/S21_XBUF2048Optional: Yes
Call by Reference: Yes
INFTY_XBUFFER4096 - C&T! - Binary buffer with 4096 byte
Data type: /BKC/S21_XBUF4096Optional: Yes
Call by Reference: Yes
INFTY_XBUFFER8192 - C&T! - Binary buffer with 8192 byte
Data type: /BKC/S21_XBUF8192Optional: Yes
Call by Reference: Yes
INFTY_XBUFFER16384 - C&T! - Binary buffer with 16384 byte
Data type: /BKC/S21_XBUF16384Optional: Yes
Call by Reference: Yes
TINFTY_XBUFFER32 - C&T! - Binary buffer with 32 byte
Data type: /BKC/S21_XBUF32Optional: Yes
Call by Reference: Yes
TINFTY_XBUFFER64 - C&T! - Binary buffer with 64 byte
Data type: /BKC/S21_XBUF64Optional: Yes
Call by Reference: Yes
TINFTY_XBUFFER128 - C&T! - Binary buffer with 128 bytes
Data type: /BKC/S21_XBUF128Optional: Yes
Call by Reference: Yes
TINFTY_XBUFFER256 - C&T! - Binary buffer with 256 byte
Data type: /BKC/S21_XBUF256Optional: Yes
Call by Reference: Yes
HRTBUFFER_P - C&T! - Buffer for PD infotype tables + personnel number
Data type: /BKC/S21_HRTBUFFER_POptional: Yes
Call by Reference: Yes
TINFTY_XBUFFER512 - C&T! - Binary buffer with 512 byte
Data type: /BKC/S21_XBUF512Optional: Yes
Call by Reference: Yes
TINFTY_XBUFFER1024 - C&T! - Binary buffer with 1024 byte
Data type: /BKC/S21_XBUF1024Optional: Yes
Call by Reference: Yes
TINFTY_XBUFFER2048 - C&T! - Binary buffer with 2048 byte
Data type: /BKC/S21_XBUF2048Optional: Yes
Call by Reference: Yes
TINFTY_XBUFFER4096 - C&T! - Binary buffer with 4096 byte
Data type: /BKC/S21_XBUF4096Optional: Yes
Call by Reference: Yes
TINFTY_XBUFFER8192 - C&T! - Binary buffer with 8192 byte
Data type: /BKC/S21_XBUF8192Optional: Yes
Call by Reference: Yes
TINFTY_XBUFFER16384 - C&T! - Binary buffer with 16384 byte
Data type: /BKC/S21_XBUF16384Optional: Yes
Call by Reference: Yes
PTAB1 - C&T! - Assignment old -> new personnel numbers
Data type: /BKC/S21_PERNR_TABOptional: Yes
Call by Reference: Yes
PTAB2 - C&T! - Assignment old -> new personnel numbers
Data type: /BKC/S21_PERNR_TABOptional: Yes
Call by Reference: Yes
SYS_FEHLER - C&T! - Interface structure for error messages
Data type: /BKC/S21_SYSTEMFEHLEROptional: Yes
Call by Reference: Yes
INFTY_XBUFFER32 - C&T! - Binary buffer with 32 byte
Data type: /BKC/S21_XBUF32Optional: Yes
Call by Reference: Yes
INFTY_XBUFFER64 - C&T! - Binary buffer with 64 byte
Data type: /BKC/S21_XBUF64Optional: Yes
Call by Reference: Yes
INFTY_XBUFFER128 - C&T! - Binary buffer with 128 bytes
Data type: /BKC/S21_XBUF128Optional: Yes
Call by Reference: Yes
INFTY_XBUFFER256 - C&T! - Binary buffer with 256 byte
Data type: /BKC/S21_XBUF256Optional: Yes
Call by Reference: Yes
Copy and paste ABAP code example for /BKC/RFC_INSERT_PD_INFTY Function Module
The ABAP code below is a full code listing to execute function module POPUP_TO_CONFIRM including all data declarations. The code uses the original data declarations rather than the latest in-line data DECLARATION SYNTAX but I have included an ABAP code snippet at the end to show how declarations would look using the newer method of declaring data variables on the fly. This will allow you to compare and fully understand the new inline method. Please note some of the newer syntax such as the @DATA is not available until a later 4.70 service pack (SP8), which i why i have stuck to the origianl for this example.| DATA: | ||||
| lv_rc | TYPE SY-SUBRC, " | |||
| lv_compress_i | TYPE SY-BATCH, " | |||
| lt_hrbuffer_p | TYPE STANDARD TABLE OF /BKC/S21_HRBUFFER_P, " | |||
| lv_xbufname_tinfty | TYPE TABNAME, " | |||
| lt_infty_xbuffer512 | TYPE STANDARD TABLE OF /BKC/S21_XBUF512, " | |||
| lt_infty_xbuffer1024 | TYPE STANDARD TABLE OF /BKC/S21_XBUF1024, " | |||
| lt_infty_xbuffer2048 | TYPE STANDARD TABLE OF /BKC/S21_XBUF2048, " | |||
| lt_infty_xbuffer4096 | TYPE STANDARD TABLE OF /BKC/S21_XBUF4096, " | |||
| lt_infty_xbuffer8192 | TYPE STANDARD TABLE OF /BKC/S21_XBUF8192, " | |||
| lt_infty_xbuffer16384 | TYPE STANDARD TABLE OF /BKC/S21_XBUF16384, " | |||
| lt_tinfty_xbuffer32 | TYPE STANDARD TABLE OF /BKC/S21_XBUF32, " | |||
| lt_tinfty_xbuffer64 | TYPE STANDARD TABLE OF /BKC/S21_XBUF64, " | |||
| lt_tinfty_xbuffer128 | TYPE STANDARD TABLE OF /BKC/S21_XBUF128, " | |||
| lt_tinfty_xbuffer256 | TYPE STANDARD TABLE OF /BKC/S21_XBUF256, " | |||
| lv_compress_t | TYPE SY-BATCH, " | |||
| lt_hrtbuffer_p | TYPE STANDARD TABLE OF /BKC/S21_HRTBUFFER_P, " | |||
| lv_table_does_not_exist | TYPE SY-BATCH, " | |||
| lt_tinfty_xbuffer512 | TYPE STANDARD TABLE OF /BKC/S21_XBUF512, " | |||
| lt_tinfty_xbuffer1024 | TYPE STANDARD TABLE OF /BKC/S21_XBUF1024, " | |||
| lt_tinfty_xbuffer2048 | TYPE STANDARD TABLE OF /BKC/S21_XBUF2048, " | |||
| lt_tinfty_xbuffer4096 | TYPE STANDARD TABLE OF /BKC/S21_XBUF4096, " | |||
| lt_tinfty_xbuffer8192 | TYPE STANDARD TABLE OF /BKC/S21_XBUF8192, " | |||
| lt_tinfty_xbuffer16384 | TYPE STANDARD TABLE OF /BKC/S21_XBUF16384, " | |||
| lt_ptab1 | TYPE STANDARD TABLE OF /BKC/S21_PERNR_TAB, " | |||
| lv_tabname_i | TYPE TABNAME, " | |||
| lt_ptab2 | TYPE STANDARD TABLE OF /BKC/S21_PERNR_TAB, " | |||
| lv_tabname_t | TYPE TABNAME, " | |||
| lt_sys_fehler | TYPE STANDARD TABLE OF /BKC/S21_SYSTEMFEHLER, " | |||
| lv_caller_is_unicode | TYPE SY-BATCH, " | |||
| lv_if_versn | TYPE PVRSN, " '01' | |||
| lt_infty_xbuffer32 | TYPE STANDARD TABLE OF /BKC/S21_XBUF32, " | |||
| lv_xbufsize_infty | TYPE /BKC/S21_XBUFSIZE, " 4096 | |||
| lt_infty_xbuffer64 | TYPE STANDARD TABLE OF /BKC/S21_XBUF64, " | |||
| lv_xbufsize_tinfty | TYPE /BKC/S21_XBUFSIZE, " 2048 | |||
| lt_infty_xbuffer128 | TYPE STANDARD TABLE OF /BKC/S21_XBUF128, " | |||
| lv_xbufname_infty | TYPE TABNAME, " | |||
| lt_infty_xbuffer256 | TYPE STANDARD TABLE OF /BKC/S21_XBUF256. " |
|   CALL FUNCTION '/BKC/RFC_INSERT_PD_INFTY' "C&T! - Insert of PD infotypes |
| EXPORTING | ||
| COMPRESS_I | = lv_compress_i | |
| XBUFNAME_TINFTY | = lv_xbufname_tinfty | |
| COMPRESS_T | = lv_compress_t | |
| TABNAME_I | = lv_tabname_i | |
| TABNAME_T | = lv_tabname_t | |
| CALLER_IS_UNICODE | = lv_caller_is_unicode | |
| IF_VERSN | = lv_if_versn | |
| XBUFSIZE_INFTY | = lv_xbufsize_infty | |
| XBUFSIZE_TINFTY | = lv_xbufsize_tinfty | |
| XBUFNAME_INFTY | = lv_xbufname_infty | |
| IMPORTING | ||
| RC | = lv_rc | |
| TABLE_DOES_NOT_EXIST | = lv_table_does_not_exist | |
| TABLES | ||
| HRBUFFER_P | = lt_hrbuffer_p | |
| INFTY_XBUFFER512 | = lt_infty_xbuffer512 | |
| INFTY_XBUFFER1024 | = lt_infty_xbuffer1024 | |
| INFTY_XBUFFER2048 | = lt_infty_xbuffer2048 | |
| INFTY_XBUFFER4096 | = lt_infty_xbuffer4096 | |
| INFTY_XBUFFER8192 | = lt_infty_xbuffer8192 | |
| INFTY_XBUFFER16384 | = lt_infty_xbuffer16384 | |
| TINFTY_XBUFFER32 | = lt_tinfty_xbuffer32 | |
| TINFTY_XBUFFER64 | = lt_tinfty_xbuffer64 | |
| TINFTY_XBUFFER128 | = lt_tinfty_xbuffer128 | |
| TINFTY_XBUFFER256 | = lt_tinfty_xbuffer256 | |
| HRTBUFFER_P | = lt_hrtbuffer_p | |
| TINFTY_XBUFFER512 | = lt_tinfty_xbuffer512 | |
| TINFTY_XBUFFER1024 | = lt_tinfty_xbuffer1024 | |
| TINFTY_XBUFFER2048 | = lt_tinfty_xbuffer2048 | |
| TINFTY_XBUFFER4096 | = lt_tinfty_xbuffer4096 | |
| TINFTY_XBUFFER8192 | = lt_tinfty_xbuffer8192 | |
| TINFTY_XBUFFER16384 | = lt_tinfty_xbuffer16384 | |
| PTAB1 | = lt_ptab1 | |
| PTAB2 | = lt_ptab2 | |
| SYS_FEHLER | = lt_sys_fehler | |
| INFTY_XBUFFER32 | = lt_infty_xbuffer32 | |
| INFTY_XBUFFER64 | = lt_infty_xbuffer64 | |
| INFTY_XBUFFER128 | = lt_infty_xbuffer128 | |
| INFTY_XBUFFER256 | = lt_infty_xbuffer256 | |
| . " /BKC/RFC_INSERT_PD_INFTY | ||
ABAP code using 7.40 inline data declarations to call FM /BKC/RFC_INSERT_PD_INFTY
The below ABAP code uses the newer in-line data declarations. This allows you to see the coding differences/benefits of the later inline syntax. Please note some of the newer syntax below, such as the @DATA is not available until 4.70 EHP 8.| "SELECT single SUBRC FROM SY INTO @DATA(ld_rc). | ||||
| "SELECT single BATCH FROM SY INTO @DATA(ld_compress_i). | ||||
| "SELECT single BATCH FROM SY INTO @DATA(ld_compress_t). | ||||
| "SELECT single BATCH FROM SY INTO @DATA(ld_table_does_not_exist). | ||||
| "SELECT single BATCH FROM SY INTO @DATA(ld_caller_is_unicode). | ||||
| DATA(ld_if_versn) | = '01'. | |||
| DATA(ld_xbufsize_infty) | = 4096. | |||
| DATA(ld_xbufsize_tinfty) | = 2048. | |||
Search for further information about these or an SAP related objects