rdisp/wp_no_enq is a SAP Parameter attribute which is used to control Number of enqueue work processes information. This is available within R/3 SAP systems depending on the version and release level.
Below is the standard documentation available and a few details of the attributes values .
rdisp/wp_no_enq profile paramerter attributes
Parameter Name: rdisp/wp_no_enq
Description: Number of enqueue work processes
Default Value: 0
Parameter Type ( See
IF_PARAMETER_TYPES)
: Integer range(INT_RANGE)
Restriction Values: 0 512
Parameter Unit:
Parameter Group: Dispatcher
CSN Component: BC-CST-DP
System-Wide parameter: No
Dynamic Parameter: No
Vector Parameter: No
Has Sub-Parameters: No
Check Function Exists: No
Parameter documentation
You can use this parameter to specify the number of enqueue work
processes on the instance.
Ensure that you only set a value > 0 on the central instance, which
provides the enqueue service (instance
rdisp/enqname> ). Normally, one enqueue work process on the central
instance is sufficient (rdisp/wp_no_enq = 1). Only in very large systems
is a higher value sometimes useful.
Caution
We now recommend the use of a standalone enqueue server (see parameter
enque/process_location> ). In this case,
set the parameter to 0 for all servers.